LOCATION 142 - ZONE TYPE 17 ALARM EVENT CODE (1 segment, numerical data)
Location 142 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 142 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 143 - ZONE TYPE 17 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
LOCATION 144 - ZONE TYPE 18 ALARM EVENT CODE (1 segment, numerical data)
Location 144 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 144 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 145 - ZONE TYPE 18 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
LOCATION 146 - ZONE TYPE 19 ALARM EVENT CODE (1 segment, numerical data)
Location 146 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 146 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 147 - ZONE TYPE 19 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
LOCATION 148 - ZONE TYPE 20 ALARM EVENT CODE (1 segment, numerical data)
Location 148 contains the event code sent for a Contact ID or SIA report. The desired event code should be chosen
from the list on page 52. The zone ID will be that zone that is in alarm. If 4+2 format is being used, the number
programmed in this location will be sent as the tens digit. When using 4+2, the digit in location 148 should be from 1-
15. The zone ID for 4+2 formats will be the ones digit of the zone that is in alarm.
LOCATION 149 - ZONE TYPE 20 CHARACTERISTIC SELECT (3 segments, feature selection data)
Use "Zone Type Characteristic Selections" described in Location 111, page 33.
Page 36

Hide quick links:

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the NX-8 - Security NetworX System and is the answer not in the manual?

Questions and answers

John L. Smith
March 10, 2025

Why is the service light illuminated on my GE Security Command Center panel?

1 comments:
Mr. Anderson
March 10, 2025

The service light on the GE Interlogix NX-8 Security NetworX System panel is illuminated for one of the following reasons:

1. Expander Trouble – If enabled, the system reports expander trouble to the central station and illuminates the service LED on the keypad. Keypads are considered expanders.
2. Fail to Communicate – If a report fails to reach the central station, the service LED is illuminated. If enabled, a Fail to Communicate code will be reported when the next report is successfully sent.

These conditions indicate a system issue that may require troubleshooting or maintenance.

This answer is automatically generated