Switch Types; Ordering Information - GE Zenith Controls ZTS Specification

Zts series automatic transfer switches
Table of Contents

Advertisement

Z
Model/Type
Z
T S
0
0 0
Standard (Open Transition)
D
0 0
Z
T S
Delayed Transition
Z
T S
C
T 0
Closed Transition
Z
B T
S
0 0
Standard (Open Transition) w/ Bypass
Z
B T
S
D 0
Delayed Transition w/ Bypass
Z
B T
S
C T
Closed Transition w/ Bypass

Switch Types

Standard: Unless otherwise noted, the standard
switch with quick transfer will be supplied.
Delayed Transition: When ordered as the ZTSD,
the delayed transition switch offers time delay during
transfer from one position to the other. This is primarily
for transfer of large motor or inductive loads.
Closed Transition: When ordered as the ZTSCT,
the closed transition switch offers two basic modes
of operation. During a failure of one source or an out
of specification condition, the
ZTSCT
as a standard delayed transition switch (
This sequence allows clear separation of an unreliable
source from an available one.
Bypass: When ordered as the ZBTS, the bypass
transition switch offers a draw-out mechanism, with
electrical and mechanical interlocks for secure removal
after load bypass. In this way the transfer switch
and/or the control panel may be tested, isolated and
removed for maintenance without load interruption.
Example
ZTSCT0B0040F-N0140STD
This number string shows the correct format for a
an Entelli-Switch 250 microprocessor control unit, Utility - Generator, 400 amps, 4 pole,
120/208V 3Ø, 4 wire, 60 Hz system with the standard group of accessories.
g
Zenith Controls
GE
A Product of GE Industrial Systems
General Electric Company
West
Street, Chicago, IL
830
40
60609 USA
th
, Fax:
773 299-6600
630 850-6899
www.geindustrial.com
B 0
Control
Config.
Panel
B 0
0
Utility - Generator
Entelli-Switch 250
Microprocessor
U
Control Unit
Utility - Utility
M
Manual
Model operates
Model).
ZTSD
S Model Automatic Transfer Switch with closed transition,
ZT
Ampere
Switched
Size
Poles
0
0
4
B
40 amps
2 Poles
0
0
8
E
80 amps
3 Poles
0
1
0
F
100 amps
4 Poles
0
1
5
150 amps
0
2
0
200 amps
0
2
2
225 amps
0
2
6
260 amps
0
3
0
300 amps
0
4
0
400 amps
0
6
0
600 amps
0
8
0
800 amps
1
0
0
1000 amps
1
2
0
1200 amps
1
6
0
1600 amps
2
0
0
2000 amps
2
6
0
2600 amps
3
0
0
3000 amps
4
0
0
4000 amps
Type 1 enclosure,
NEMA

Ordering Information

Enclosure
Operational
Type
Voltage
A B
N
0 1
Type 1 Enclosed
Consult Table Below
N 1 2
Type 12 Enclosure
N 3 R
Type 3R Enclosure
N 0 4
Type 4 Enclosure
N 4 X
Type 4X Enclosure
X 0 0
Open Style Unit
A
B
Voltage
Phase
1
0
120
1
2
0
120/240
1
2
1
120/208
3
3
0
240
3
3
1
208
3
3
2
220
3
3
3
120/240
3
3
4
110/220
3
3
5
139/240
3
3
8
120/240
3
4
0
120/208
3
4
1
127/220
3
4
2
127/220
3
5
0
480
3
5
1
440
3
5
2
440
3
5
5
460
1
5
7
480
1
5
8
254/440
3
6
0
575
3
6
1
347/600
3
7
0
277/480
3
7
1
277
1
7
4
266/460
3
7
5
460
3
8
0
120/240
2
8
2
380
1
9
0
240/416
3
9
1
220/380
3
9
2
220/380
3
9
3
240/416
3
9
7
380
3
Note: Operating voltage must be specified at time of order.
Only the most common voltages are shown above.
Contents contained in this document are subject to
change without notice. Contact GE to verify details.
ZTS Series
Accessories
M
S
T D
S
M
E
X E
S
C
O N
M
S
M
S
E N
S
M
S
P E
S
P
S G
M
S
Then choose
additional
accessories
Config.
Hz
2 wire
60
3 wire
60
3 wire
60
3 wire
60
3 wire
60
3 wire
50
4 wire
50
4 wire
60
4 wire
60
4 wire
60
4 wire
60
4 wire
60
4 wire
50
3 wire
60
3 wire
60
3 wire
50
3 wire
50
2 wire
60
4 wire
60
3 wire
60
4 wire
60
4 wire
60
2 wire
60
4 wire
60
3 wire
60
4/5 wire
60
2 wire
50
4 wire
60
4 wire
60
4 wire
50
4 wire
50
3 wire
60