TECHNICAL DATA

DIMENSIONS
Overall
Height to hotplate
Space for fixing at hotplate level
Space for fixing above hotplate level 100mm each side of appliance
Minimum space above grill
Minimum distance from rear wall
Weight of appliance
CONNECTIONS
Gas
Electric
IGNITION
Spark Generator
Battery
GRILL
Heat Input
Injector Marking
R H G 5 0 G
Height
1462mm (nominal)
907mm nominal -
see important note 'Location of the Appliance' (see Page 35).
500mm
20mm
59.3kg
Rear left hand side of appliance at hotplate level
Rc½ (½" B.S.P. female)
None
APCO 6BG6893
1.5 volt AA size
Natural Gas
3.0kW (10236 Btu/h)
120
33
Width
498mm
2mm minimum
clearance
L.P. Gas
2.75kW (197.5g/h)
80
Depth
600mm
(from elbow
to front of door panel)
600mm
Nominal