Sony MZ-N505 Service Manual page 15

Service manual
Hide thumbs Also See for MZ-N505:
Table of Contents

Advertisement

5. The display changes a shown below each time the
[MENU/ENTER]
key .
• Address & Adjusted Value Display
Set LCD display
011
C68S1B
item number
address
• Jitter Value & Adjusted Value Display
Set LCD display
011
0FEJ1B
item number
jitter value adjusted value
• Block Error Value & Adjusted Value Display
Set LCD display
011
063B1B
item number
block error
value
• ADIP Error Value & Adjusted Value Display
Set LCD display
011
081A1B
ADIP error
item number
value
• Focus Drive Value & Adjusted Value Display
Set LCD display
011
000F1B
item number
Focus
drive value
• Item Title Display
Set LCD display
011
LrefPw
item number
However in the power mode (item number 700's), only the
item is displayed.
6. Quit the manual mode, and press the
test mode (display check mode).
adjusted value
adjusted value
adjusted value
adjusted value
item title
x
key to return to the
OVERALL ADJUSTMENT MODE
Mode to adjust the servo automatically in all items.
Normally, automatic adjustment is executed in this mode at the
repair.
For further information, refer to "SECTION 5 ELECTRICAL
ADJUSTMENTS" (see page 19).
SELF-DIAGNOSIS RESULT DISPLAY MODE
This set uses the self-diagnostic function system in which if an
error occurred during the recording or playing, the mechanism
control block and the power supply control block in the micro-
computer detect it and record its cause as history in the nonvola-
tile memory.
By checking this history in the test mode, you can analyze a fault
and determine its location.
Total recording time is recorded as a guideline of how long the
optical pickup has been used, and by comparing it with the total
recording time at the time when an error occurred in the self-
diagnosis result display mode, you can determine when the error
occurred.
Clear both self-diagnosis history data and total recording time, if
the optical pickup was replaced.
• Self-Diagnosis Result Display Mode Setting Method
1. Set the test mode (see page 13).
2. In the display check mode,
self-diagnosis result display mode where the LCD display as
shown below.
Set LCD display
0XX
1 0000
error display code
history code
3. Then, each time the
>
key is pressed, LCD display descends
by one as shown below. Also, the LCD display ascends by one
when the
.
key is pressed.
0XX
0XX
0XX
0XX
0XX
XX
: Error code
* * * * : Total recording time
[MENU/ENTER]
If the
key is pressed with this display, the LCD
switches to the simple display mode.
4. Quit the self-diagnosis result display mode, and press the
to return to the test mode (display check mode).
MZ-N505
[MENU/ENTER]
key activates the
Total recording time
when error occurred
1
1 ****
N ****
N1****
N2****
R_****
1
x
key