Is the drive enclosure back panel OK LED off?
Answer
No
Yes
Is the drive enclosure Fault/Service Required LED amber?
Answer
No
Yes (blinking)
Yes
Possible Reasons
System functioning properly.
The power supply unit or a fan is
operating at an unacceptable
voltage/RPM level, or has failed.
Possible Reasons
System functioning properly.
One of the following errors
occurred:
•
Hardware-controlled
power-up error
•
Cache flush error
•
Cache self-refresh error
A fault occurred.
If installing an I/O module FRU,
the module has not gone online
and likely failed its self-test.
HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide
Actions
No action required.
When isolating faults in the power
supply, remember that the fans in both
modules receive power through a
common bus on the midplane, so if a
power supply unit fails, the fans
continue to operate normally.
•
Check that the power supply FRU is
firmly locked into position.
•
Check that the AC cord is
connected to a power source.
•
Check that the AC cord is
connected to the power supply.
Actions
No action required.
•
Check the event log for specific
information regarding the fault.
•
Isolate the fault.
•
Contact an authorized service
provider for assistance.
•
Replace if necessary.
•
Check the event log for specific
information regarding the fault.
•
Isolate the fault.
•
Contact an authorized service
provider for assistance.
•
Replace if necessary.
•
If installing an I/O module FRU, try
removing and reinstalling the new
I/O module, and check the event
log for errors.
47