Is The Drive Enclosure Back Panel Ok Led Off; Is The Drive Enclosure Fault/Service Required Led Amber - HP StorageWorks 2000fc - G2 Modular Smart Array User Manual

Hp storageworks 2312fc and 2324fc modular smart array user guide (500910-001, january 2009)
Hide thumbs Also See for StorageWorks 2000fc - G2 Modular Smart Array:
Table of Contents

Advertisement

Is the drive enclosure back panel OK LED off?

Answer
No
Yes

Is the drive enclosure Fault/Service Required LED amber?

Answer
No
Yes (blinking)
Yes
Possible Reasons
System functioning properly.
The power supply unit or a fan is
operating at an unacceptable
voltage/RPM level, or has failed.
Possible Reasons
System functioning properly.
One of the following errors
occurred:
Hardware-controlled
power-up error
Cache flush error
Cache self-refresh error
A fault occurred.
If installing an I/O module FRU,
the module has not gone online
and likely failed its self-test.
HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide
Actions
No action required.
When isolating faults in the power
supply, remember that the fans in both
modules receive power through a
common bus on the midplane, so if a
power supply unit fails, the fans
continue to operate normally.
Check that the power supply FRU is
firmly locked into position.
Check that the AC cord is
connected to a power source.
Check that the AC cord is
connected to the power supply.
Actions
No action required.
Check the event log for specific
information regarding the fault.
Isolate the fault.
Contact an authorized service
provider for assistance.
Replace if necessary.
Check the event log for specific
information regarding the fault.
Isolate the fault.
Contact an authorized service
provider for assistance.
Replace if necessary.
If installing an I/O module FRU, try
removing and reinstalling the new
I/O module, and check the event
log for errors.
47