Are both drive module LEDs off (Online/Activity and Fault/UID)?
Answer
Yes
Is the drive module Fault/UID LED blinking amber?
Answer
No, but the
Online/Activity LED is
blinking.
Yes, and the
Online/Activity LED is off.
Yes, and the
Online/Activity LED is
blinking.
Is a connected host port's Host Link Status LED off?
Answer
No
Yes
Possible Reasons
•
There is no power.
•
The drive is offline.
•
The drive is not configured.
Possible Reasons
The drive is rebuilding.
The drive is offline. A predictive
failure alert may have been
received for this device.
The drive is active, but a
predictive failure alert may have
been received for this device.
Possible Reasons
System functioning properly.
The link is down.
HP StorageWorks 2312fc and 2324fc Modular Smart Array user guide
Actions
•
Check that the drive is fully inserted
and latched in place, and that the
enclosure is powered on.
Actions
No action required.
NOTE:
Do not remove a drive that is
rebuilding. Removing a drive might
terminate the current operation and
cause data loss.
•
Check the event log for specific
information regarding the fault.
•
Isolate the fault.
•
Contact an authorized service
provider for assistance.
•
Check the event log for specific
information regarding the fault.
•
Isolate the fault.
•
Contact an authorized service
provider for assistance.
Actions
No action required.
•
Check cable connections.
•
Reseat cables.
•
Replace cables.
•
In SMU, review the event logs for
indicators of a specific fault in a
host data path component.
45
Need help?
Do you have a question about the StorageWorks 2000fc - G2 Modular Smart Array and is the answer not in the manual?
Questions and answers