Nvidia quadro fx 560m installation
Hide thumbs Also See for Xw460c - ProLiant - Blade Workstation:

Advertisement

Insert the second Quadro FX 560M graphics board in the Mezzanine 2 connector using the three captive retaining
screws as shown below. Ensure that the graphics board connector is firmly seated in the Mezzanine 2 connector.
Reinstall the blade workstation in the rack by performing the following steps:
1.
Install the blade workstation access panel.
2.
Install the blade workstation in the rack.
3.
Power up the blade workstation, and select Setup Mode during the boot process. This is in preparation for
installing the required version of RGS in Step 6, and assumes the continued use of the iLO 2 Remote
Console.
Step 6—Ensure that RGS 5.1.1 (or later) is installed, and verify RGS
operation
The final step is to ensure that RGS 5.1.1 (or later) is installed on the blade workstation—this is required for dual-
Quadro FX 560M graphics. Perform the following four steps to determine your RGS version, install RGS (if
necessary), and verify RGS operation.
a.
To view the current RGS version, right-click on the RGS icon in the system tray, and select About to display
the RGS version. If the version is 5.1.1 or later, skip to step "d".
b.
If you have purchased RGS update subscription services or RGS software assurance, you can download
RGS Workstation 5.1.1 (or later) for free from your subscription website. Otherwise, you'll need to purchase
RGS 5.1.1 (or later) from http://www.hp.com/go/softwaredepot.
c.
After downloading RGS, follow the instructions in the RGS User Guide to install the RGS Sender on your
blade workstation.
d.
Reboot the blade workstation. As the blade workstation reboots, change the Remote Console Mode to User
Mode. Follow your normal RGS connection procedure to verify that an RGS connection can be made to the
blade workstation.
- 10 -