C. Rebuilding an Array
Rebuilding is the process of restoring data to a hard drive from other drives in the array. Rebuilding applies only
to fault-tolerant arrays such as RAID 1 arrays. The procedures below assume a new drive is added to replace a
failed drive to rebuild a RAID 1 array. (Note: The new drive must have equal or greater capacity than the old one.)
Turn off your computer and replace the failed hard drive with a new one. Use either the RAID setup utility or
the GIGABYTE RAID CONFIGURER utility in the operating system to perform the rebuild.
• Rebuilding with the RAID setup utility
Step 1:
When the message "Press <Ctrl-G> to enter RAID Setup Utility" appears, press <Ctrl> + <G> to enter the util-
ity. In the Main Menu block, select Rebuild Mirror Drive and press <Enter>. The selection bar will move to
the degraded array. Press <Enter> again.
[ Main Menu ]
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
Solve Mirror Conflict
Rebuild Mirror Drive
Save And Exit Setup
Exit Without Saving
[ RAID Disk Drive List ]
Model Name
RDD0: GRAID
[ fg TAB]-Switch Window
Step 2:
The selection bar will then move to new hard drive in the Hard Disk Drive List block. Press <Enter> to start
the RAID rebuilding process. The rebuilding progress is displayed at the bottom of the screen. When done,
the status of the array will display as Normal.
[ Main Menu ]
Create RAID Disk Drive
Delete RAID Disk Drive
Revert HDD to Non-RAID
Solve Mirror Conflict
Rebuild Mirror Drive
Save And Exit Setup
Exit Without Saving
[ RAID Disk Drive List ]
Model Name
RDD0: GRAID
Rebuilding....35%, please wait....
Appendix
Gigabyte Technology Corp. RAID Setup Utility v1.07.06
[ Hard Disk Drive List ]
Model Name
HDD0: ST3120026AS
HDD1: ST3120026AS
RAID Level
1-Mirror
[ hi ]-Select RAID
Gigabyte Technology Corp. RAID Setup Utility v1.07.06
[ Hard Disk Drive List ]
Model Name
HDD0: ST3120026AS
HDD1: ST3120026AS
RAID Level
1-Mirror
- 70 -
Capacity
Status
120 GB
Degraded
[ENTER]-Action
Capacity
Status
120 GB
Degraded
Capacity
Type/Status
120 GB
RAID Inside
120 GB
Non-RAID
Members(HDDx)
0?
[ESC]-Exit