COMPONENTS IDENTIFIED BY SHADING AND MARKED THE SCHEMATIC DIAGRAMS, EXPLODED VIEWS AND IN THE PARTS LIST ARE CRITICAL FOR SAFE OPERATION. REPLACE THESE COMPONENTS WITH SONY PARTS WHOSE PART NUMBERS APPEAR AS SHOWN IN THIS MANUAL OR IN SUPPLEMENTS PUBLISHED BY SONY.
Due to the higher melting point of Lead Free Solder the soldering iron tip temperature needs to be set to 370 degrees centigrade. This requires soldering equipment capable of accurate temperature control coupled with a good heat recovery characteristics. For more information on the use of Lead Free Solder, please refer to http://www.sony-training.com - 3 -...
SE1A RM-ED009 CONNECTORS 21 Pin Connector (SCART) Pin No Signal Signal level Audio output B Standard level : 0.5V rms (right) Output impedence : Less than 1kohm* Audio input B Standard level : 0.5V rms (right) Output impedence : More than 10kohm* Audio output A Standard level : 0.5V rms (left)
Page 6
SE1A RM-ED009 HDMI Connector Pin No Signal Assignment Pin No Signal Assignment TMDS Data2+ TMDS Clock Shield TMDS Data2 Shield TMDS Clock- TMDS Data2- TMDS Data1+ Reserved (N.C. on device) TMDS Data1 Shield TMDS Data1- TMDS Data0+ DDC/CEC Ground TMDS Data0 Shield +5V Power TMDS Data0- Hot Plug Detect...
SE1A RM-ED009 SE1A SELF DIAGNOSTIC SOFTWARE The identification of errors within the SE1A chassis is triggered in one of two ways :- 1: Busy or 2: Device failure to respond to IIC. In the event of one of these situations arising the software will first try to release the bus if busy (Failure to do so will report with a continuous flashing LED) and then communicate with each device in turn to establish if a device is faulty.
SE1A RM-ED009 SECTION 3 CIRCUIT ADJUSTMENTS 3-1. Electrical Adjustments Service adjustments to this model can be performed using the supplied remote Commander RM-ED009. How to enter into the Service Mode Turn on the main power switch. Press the following sequence of buttons on the Remote Commander.
SE1A RM-ED009 3-2. TT MODE TT mode is available by setting the TV for operation in Service Mode [ As shown on Page 17 ] , OSD ‘TT’ appears. The functions described below are available by selecting the two numbers. To release the ‘Test mode 2’, press 00, 10, 20 ... twice or switch the TV set into Stand-by mode.
SE1A RM-ED009 3-3. TT OSD Labels A E P T T - " E C S C B A N o r m D D C (10) (11) (12) (13) (14) (15) C l k (16) (17) (18) (19) (20) (21) (22) W c g...
SE1A RM-ED009 4-1. BLOCK DIAGRAM , sw itch-buttons , SIR C S, LED . H D M I 3 Front A V CI bu ffers Elp ida R G B 4+ 4+ 4+ 5(c trl) EDD12 16 AAT A D ata, A ddr, DDR 128M b C ontrol C V B S D ig ita l R F...
Page 58
AGNDV IC7100 UPD61123F1-100-KA3-A AGNDP GND_1 CHIP 1/16W R7150 CHIP 1/16W R7151 GND_1 9D/13 COMPONENTS MARKED AS XX REFER TO PARTS LIST, WILL ONLY BE LISTED IF FITTED BC.SE1A ~ BC Board Schematic Diagram [ Tuner, Audio/Video Processor, HDMI & PC Input ] Page 9D/13 ~ - 58 -...
SECTION 5 EXPLODED VIEWS NOTE : Non-serviceable items with no part number and no Items marked “*” are not stocked description are not stocked because they are not since they are seldom required for required for routine service. routine service. Some delay should The construction parts of an assembled part are indicated be anticipated when ordering these with a collation number in the remarks column.
SECTION 6 ELECTRICAL PARTS LIST PARTS LISTING TABLE OF CONTENTS Page U2 BOARD COMPLETE Parts List : ....................105 BC BOARD COMPLETE Parts List : ....................106 G3 BOARD COMPLETE Parts List : KDL-40/46S30XX only ............... 124 D1 BOARD COMMON Parts List : Parts common to all models listed in this manual ......