Brother BAS-761 Instruction Manual page 46

Automatic pocket setter
Hide thumbs Also See for BAS-761:
Table of Contents

Advertisement

12. Table of error code
Error code
E – 800
EMERGENCY STOP button pressed
E – 801
EMERGENCY STOP button pressed during sewing
E – 802
EMERGENCY STOP button pressed during programming
E – 803
EMERGENCY STOP button pressed during programming
E – 810
EMERGENCY STOP button is not connected
E – 820
No air, or air chuck is turned off
E – 821
No air, or air chuck is turned off
E – 830
X right overtravel switch activated
E – 840
X left overtravel switch activated
E – 850
Y up overtravel switch activated
E – 860
Y down overtravel switch activated
E – 870
X motor problem
E – 880
Y motor problem
E – 890
Machine head motor problem
E – 900
Outer work clamp cylinder malfunction or sensor malfunction
E – 901
Inner work clamp cylinder malfunction or sensor malfunction
E – 902
Gauge forward/back cylinder malfunction or sensor malfunction
E – 903
Base 10 cylinder malfunction or sensor malfunction
E – 910
X axis positioning error
E – 920
Y axis positioning error
E – 960
Clamp-in sensor malfunction
E – 970
Clamp malfunction
* If the primary-side voltage is lower than the rated level at low temperatures, the error message "E-890" may appear
at the sewing start. If this happens, set DIP switch A-7 to ON.
39
Contents
BAS-761
Reset
Yes
Yes
No
Yes
No
Yes
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No
No

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents