3. TECHNICAL BRIEF
3.12 Vibrator Interface
This handset has vibrator operation. Control signal is controlled by EGold-voice with PWM.
VIBRATOR
VBAT
C302
27p
(50V,J,NP0)
CN300
VIBRATOR
Figure 3-12 Vibrator interface
VBAT
1
2
C305
R305
27p
(1608)
10
R306
Q300
2SC5585
1K