Troubleshooting Checklist; Connect Wiring - GE JV367HWW Owners And Installation Manual

Ge deluxe range hood
Table of Contents

Advertisement

INSTALL LIGHT BULB
19
NOTE: A light bulb is not shipped with the hood.
Obtain one locally. Purchase and install a type A15
incandescent light bulb with an ordinary screw
base, not more than 60 Watts, or a type A17 or T2
Compact Fluorescent (CFL) light bulb with an ordinary
screw base, not more than 13 Watts. NOTE: Use only
incandescent bulbs in models RN328, JN327 and JV338.
IMPORTANT: For installation, handling and disposal
precautions, refer to the fluorescent bulb packaging literature.
When using an energy saving bulb in your GE hood, make sure you use
GE Long Life Energy
Smart
Spiral
T2
®
FOLLOW ELECTRICAL CODE
20
Complete the electrical wiring according to National
Electrical Code and local codes.
NOTE: This hood must be permanently grounded.
Connect house wiring (120 VAC) to hood wiring.

CONNECT WIRING

21
Connect house black to hood black wire, house white
to hood white wire and house ground under green
ground screw. Securely tighten the strain relief clamp
onto the house wiring.
WARNING:
ALUMINUM HOUSE WIRING TO THESE COPPER LEADS
CAN RESULT IN A SERIOUS PROBLEM. USE ONLY
CONNECTORS DESIGNED FOR JOINING COPPER TO
ALUMINUM AND FOLLOW THE MANUFACTURER'S
RECOMMENDED PROCEDURE CLOSELY.
Installation Instructions
or
GE Long Life Energy
Smart
A17
Available at
www.gelighting.com
Green ground
screw
IMPROPER CONNECTION OF
REPLACE WIRING COVER
22
REPLACE FILTER
23
Make sure fan blade turns freely and replace the
filter. NOTE: Install the metal grease filter if ducted or
the charcoal filter if recirculated.
The installation is complete. Turn on power at service
panel, and test for proper operation.

TROUBLESHOOTING CHECKLIST

If the hood seems to be operating at high speed when
the control is not set on high, or if ventilation seems
❏ Knockouts not removed from hood.
❏ Damper blade not opening.
❏ Reduced airflow because the duct is too small or the
duct length is too long.
❏ The duct is blocked.
❏ Undersized or restrictive wall or roof cap.
❏ Fan may be hitting the filter. Turn off the fan and
remove the filter. Bend the filter down slightly in the
center (into a dome shape) to allow fan clearance.
Reinstall and adjust as needed.
❏ Switch power off at the service panel and lock the
service disconnecting means to prevent power from
being switched on accidentally. When the service
disconnecting means cannot be locked, securely
fasten a prominent warning device, such as a tag, to
the service panel.
❏ Check the wiring connections. See the CONNECT
WIRING section in these Installation Instructions.
14
Wiring cover
Metal grease filter or charcoal filter