SWiTCH TRiGGER
See Figure 7.
To turn the inflator ON, depress the switch trigger. To turn
it Off, release the switch trigger.
LOCk-ON BUTTON
See Figure 7.
The inflator is equipped with a lock-on button for continuous
inflating over extended periods of time. The lock-on button
is located on top of the handle.
To lock-on:
 Depress the switch trigger.
 Push the lock-on button forward.
 Release the switch trigger and the inflator will continue
running.
 To release the lock, depress the switch trigger again.
iNfLATiNG WiTH THE LOW PRESSURE AiR
HOSE
See Figure 8.
The low pressure air hose is used to inflate low pressure
items, such as air mattresses, pools, and floats.
A pinch valve adaptor comes as part of the small inflatable
nozzle assembly that is attached to the end of the low pres-
sure air hose. The pinch valve adaptor is used for items that
have a smaller air opening or pinch valve.
 Insert pinch valve adaptor into pinch valve, insuring that
the tip of the
adaptor is inserted past the inner "flap"
inside the valve. When inflating, ensure that the tip is not
blocked during inflation.
CAUTiON:
Always leave low pressure hose free of obstructions and
with pinch valve adaptor off when not in use. Overheating
could occur low pressure hose is blocked.
iNfLATiNG WiTH THE HiGH PRESSURE AiR
HOSE
See Figure 9 - 10.
The air chuck on the high pressure air hose can be used
without adaptors to inflate tires or with any application that
has a valve stem that fits the air chuck opening.
 Position air chuck clamp in the unlock position
perpendicular to the high pressure air hose.
 Place air chuck on valve stem.
 Push air chuck down so that the threaded section of the
valve stem is inside the air chuck.
 Clamp the end of the air chuck down onto the valve
stem by pressing air chuck clamp down until it stops or
is parallel with the high pressure air hose.
NOTE: When inflating items of 10 PSI., .69 BAR, .70 KG/CM
or less, inflate in short bursts and check after each burst
by feel or with a calibrated measuring device to determine
accurate pressure.
OPERATiON
AIR
HOSE
AIR CHUCK
VALVE STEM
AIR
HOSE
PRESTA VALVE
ADAPTOR
PRESTA
VALVE

1
LOCK-ON
BUTTON
TO
LOCK
UNLOCKED
SWITCH
TRIGGER
LOW
PRESSURE
HOSE
TO
LOCK
TO
LOCK
Fig. 7
PINCH
VALVE
ADAPTOR
Fig. 8
TO
UNLOCK
AIR
CHUCK
CLAMP
Fig. 9
TO
UNLOCK
AIR
CHUCK
CLAMP
AIR
CHUCK
LOCKING
NUT
Fig. 10