Download Print this page

Paradyne 3000 Installation Instructions page 4

Power transformer unit
Hide thumbs Also See for 3000:

Advertisement

3. At the rear of the carrier, use a screwdriver to
engage and tighten the two captive screws that
fasten the power transformer unit to the carrier.
P20 P19
P26
P25
P24
J2
P22
J1
Captive
4. Plug the power transformer output connectors into
the P19 and P20 connectors on the backplane and
latch them.
CAUTION
The power cord contains a
3-wire grounding-type plug
which has a grounding pin.
This is a safety feature.
Grounding of the carrier is
vital to ensure safe operation.
Do not defeat the purpose of
the grounding plug by
modifying it or by using an
adapter.
Prior to installation, use an
outlet tester or voltmeter to
check the ac receptacle for
earth ground. If the power
source does not provide a
ground connection, consult an
electrician to determine
another method of grounding
the carrier before proceeding
with the installation.
3000-A2-GZ52-00
P23
P21
Screws
496-14894
March 1996
5. Plug the appropriate end of the power cord into
the ac receptacle on the carrier.
P20 P19
AC
Receptacle
P26
P25
J2
P22
6. Plug the other end of the power cord into one of
the convenience outlets inside the cabinet, or to an
external ac outlet.
7. If you are not installing a fan module or SDCP,
return to the front of the carrier and replace the
cover plate. Tighten the four captive screws.
Refer to Document Number 3000-A2-GA31,
COMSPHERE 3000 Series Carrier Installation Manual,
for additional carrier installation details.
P20 P19
P24
P23
J1
P21
496-14804-01
3

Advertisement

loading

This manual is also suitable for:

Comsphere 3000 series3000-f1-200