Checkout; Heating; Cooling; Heating Cycle Rates - Honeywell T8401C1015 - Electronic Thermostat - 1 Heat/1Cool Installation Instructions Manual

Installation instructions
Table of Contents

Advertisement

T8400C, T8401C ELECTRONIC THERMOSTATS
NOTE: In installer setup mode only, each press of the
key momentarily displays 01. Each press of
the
key momentarily displays 02. When the
keys are released, these two-digit codes are no
longer displayed.
3. Press the
key. Factory information is displayed.
A typical example is shown, but information dis-
played varies by model. This information is for fac-
tory use only.
4. Press the
key again to display °C or °F.
5. Press the
key to change the °C or °F indication.
6. Press the
key to display the heat cycle rate of 1,
3, 4, 5, 6, 9, or 12. To change the heat cycle rate,
press the
key to scroll between 1, 3, 4, 5, 6, 9, or
12. Stop scrolling when the desired rate is dis-
played. See Table 1 for the cycle rate options and
the corresponding system equipment.
7. Press the
key to display heating/cooling temper-
ature control default..
8. Press the
key again to change heating/cooling
temperature control to C1 or C3.
C1 = Standard heating/cooling temperature
control.
C3 = Aggressive heating/cooling temperature
control (can cause room temperature to
overshoot the setpoint).
9. Press the
key again. Factory information (varies
by model) is shown.
69-1740
M14687
M14688
M14689
M14690
M18419A
M18420
Table 1. Heating Cycle Rates.
System
Steam, gravity
Hydronic heat, condensing gas
a
furnace
Gas or oil forced air
Electric heat
b
Special applications
a
High efficiency furnace.
b
Refer to equipment manufacturer's instructions.
10. Press the
key to save all changes, exit installer
setup mode and return to normal operation.
NOTE: After exiting installer setup mode, slide the
System switch to the desired position and
change the setpoint to the desired room
temperature.

CHECKOUT

Heating

1. Slide the SYSTEM switch to Heat and the FAN
switch to Auto.
2. Press and hold the
setting several degrees above the room tempera-
ture. After approximately ten seconds, the heating
equipment should start. In conventional systems,
the system turns on the fan through the use of a
time delay relay or through a limit control. When
using an electric heat thermostat, the fan starts
immediately.
3. Press the
key to lower the temperature setting
below the room temperature. Heating equipment
should stop.

Cooling

CAUTION
Low Temperature Hazard.
Operating at too low of an outdoor
temperature may cause compressor damage.
Do not operate cooling if outdoor temperature is
below 50°F (10°C). Refer to manufacturer's
recommendations.
• For compressor protection, during power
interruption and on initial startup, the T8400C
and T8401C Thermostats go into a five-minute
delay. During this delay, the cooling icon (a
snowflake ) flashes.
1. Slide the SYSTEM switch to Cool and the FAN
switch to Auto.
2. Press the
key to lower the temperature setting
several degrees below the room temperature. After
approximately five minutes, the cooling equipment
should start. The fan starts and stops with the cool-
ing equipment.
6
Cycles Per Hour
1
3
6
9
4, 5, 12
key to raise the temperature

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for: