Dell PowerEdge 2900 Information Update page 17

Information update
Hide thumbs Also See for PowerEdge 2900:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
Table 1-2. LCD Status Messages (continued)
Code
Text
E171F
PCIE Fatal Err
B## D## F##
PCIE Fatal Err
Slot #
E1914
DRAC5 Conn2
Cbl
E1B01
USB#
Overcurrent
MBE DIMM # & # One of the two indicated
E2110
Causes
The system BIOS has
reported a PCIe fatal error
on a component that
resides in PCIe
configuration space at bus
##, device ##, function
##.
The system BIOS has
reported a PCIe fatal error
on a component that
resides in the specified
slot.
DRAC 5 cable is missing
or disconnected.
Device plugged in the
specified USB port caused
an overcurrent condition.
DIMMs has had a memory
multi-bit error (MBE).
Corrective Actions
Remove and reseat the
PCIe expansion cards.
If the problem persists,
see "Troubleshooting
Expansion Cards" in
the Hardware Owner's
Manual.
Reinstall the expansion-
card riser. See "Expansion
Card Risers" in the
Hardware Owner's
Manual.
If the problem persists,
the riser card or system
board is faulty. See
"Getting Help" in the
Hardware Owner's
Manual.
Reconnect the cable. See
"Installing a RAC Card"
in the Hardware Owner's
Manual.
Reseat the device cable.
If the problem persists,
replace or remove the
device.
See "Troubleshooting
System Memory" in
the Hardware Owner's
Manual.
Information Update