PERFORMANCE DATASHEETS
Base Grille Water Filtration System
Model T2WG2L/T2RFWG2
Capacity
200 Gallons (758 Liters)
Model T2WG2/T2RFWG2
Capacity
200 Gallons
(758 Liters)
System
tested and certified
by NSF International
against
NSF/ANSI
Standard
42 for the reduction
of Chlorine
Taste and Odor, Particulate
Class I1"; and against
NSF/ANSI
Standard
53 for the reduction
of Mercury,
Benzene,
Toxaphene,
O-dichlorobenzene,
and Carbofuran.
This system
has been tested according
to NSF/ANSI
Standards
42 and 53 for the reduction
of the substances
listed below. The
concentration
of the indicated
substances
in water entering
the system
was reduced
to a concentration
less than or equal to the
permissible
limit for water leaving the system,
as specified
in NSF/ANSI
Standards
42 and 53.
Substance
Reduction
Aesthetic
Effects
Chlorine Taste/Odor
Particulate Class I1"
Contaminant
Reduction
Lead: @ pH 6.5***
Lead: @ pH 8.5***
Mercury: @ pH 6.5
Mercury: @ pH 8.5
Benzene
O-Dichlorobenzene
Toxaphene
Carbofuran
NSF Reduction
Requirements
50% reduction
85% reduction
NSF Reduction
Requirements
0.010 mg/L
0.010 mg/L
0.002 mg/L
0.002 mg/L
0.005 mg/L
0.6 mg/L
0.003 mg/L
0.04 mg/L
Average
Influent Challenge
Maximum
Average
Influent
Concentration
Effluent
Effluent
2.0182 mg/L
2.0 mg/L + 10%
0.06 mg/L **
0.0536 mg/L
1333333 #/mL
At east 10,000 part c es/mL
6600 #/mL
2325 #/mL
Average
Influent
0.1533 mg/L
0.1400 mg/L
0.0058 mg/L
0.0059 mg/L
0.0154 mg/L
1.7571 mg/L
0.015 mg/L
0.0819 mg/L
Influent Challenge
Concentration
0.15 mg/L_+ 10%
0.15 mg/L_+ 10%
0.006 mg/L _+10%
0.006 mg/L _+10%
0.015 mg/L _+10%
1.8 mg/L _+10%
0.015 mg/L _+10%
0.08 mg/L _+10%
Maximum
Effluent
0.0005 mg/L
0.0007 mg/L
0.0002 mg/L
0.0005 mg/L
0.0012 mg/L
0.0250 mg/L
0.001 mg/L
0.0400 mg/L
Average
Effluent
0.0005 mg/L
0.0006 mg/L
0.0002 mg/L
0.0003 mg/L
0.0006 mg/L
0.0066 mg/L
0.001 mg/L
0.0213 mg/L
Minimum %
Reduction
97.03
99.51
Minimum %
Reduction
99.67
99.50
96.54
91.57
92.22
98.58
93.33
51.13
Average %
Reduction
97.34
99.83
Average %
Reduction
99.67
99.57
96.54
94.92
96.34
99.63
93.33
74.00
Test Parameters: pH = 7.5 + 0.5 unless otherwise noted. Flow = 0.85 gpm (3.2 Lpm). Pressure =
Temp. = 68°F to 71.6°F (20°C to 22°C).
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Use replacement cartridge T2RFWG2, part #4396841.
In Canada, use replacement cartridge T2RFWG2, part
#4396841B. 2008 suggested retail price of $39.99 U.S.A./
$49.99 Canada. Prices are subject to change without notice.
Model T2WG2L:
Style
1 - When the filter indicator
reads 10%,
order a new filter. When the filter indicator
reads 0%, it is
recommended
that you replace the filter.
Style 2 - When the filter indicator
light changes
from green to
yellow, order a new filter. When the filter indicator
light changes
from yellow to red, it is recommended
that you replace the filter.
Style 3 - When the water
filter status
display
changes
from
"GOOD"
to "ORDER,"
order
a new filter. When the filter
indicator
reads
"REPLACE,"
it is recommended
that you
replace
the filter.
Model T2WG2: Change the water filter cartridge every
6 months depending upon your usage. If the water flow to the
water dispenser or ice maker decreases noticeably before
6 months have passed, replace the water filter cartridge more
often.
60 psig (413.7 kPa).
The product is for cold water use only.
Do not use with water that is microbiologically
unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the "Assistance
or Service" section for the
Manufacturer's
name, address and telephone number.
Refer to the "Warranty" section for the Manufacturer's
limited
warranty.
Application Guidelines/Water
Supply Parameters
Water Supply
City or Well
Water Pressure
30 - 120 psi (207 - 827 kPa)
Water Temperature
33 ° - 100°F (0.6 ° - 37.8°C)
Service Flow Rate
0.85 gpm (3.2 Lpm) @ 60 psi
These contaminants
are not necessarily in your water supply.
While testing was performed under standard laboratory
conditions, actual performance may vary.
*Class II particle size: 1 um to <5 um
**Test requirement
is at least 100,000 particles/mL
of AC Fine Test Dust.
***Compliant
for Lead reduction requirements
under NSF/ANSl Standard 53 as tested by Pace Analytical Services, Inc.