Performance Data Sheet
Model: GE RPWF
Use Replacement Cartridge RPWF.
The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible
limit for water leaving the system as specified in NSF/ANSI Standard 42 and Standard 53. System tested and certified by NSF International against
NSF/ANSI Standard 42 and Standard 53 for the reduction of substances listed below.
Capacity 170 Gallons (643.5 Liters).
Substance Tested
for Reduction
Average Infl uent
Chlorine Taste and Odor
Nominal Particulate
Class I, , ≥0.5 to < 1.0 μm 7,633,333 pts/mL
Asbestos
Atrazine
Benzene
Carbofuran
Cyst*
104,750 cysts/L
Lead pH @6.5
Lead pH @8.5
Mercury @ pH 6.5
Mercury @ pH 8.5
Lindane
P-Dichlorobenzene
Toxaphene
2, 4-D Reduction
VOC
*Based on the use of Cryptosporidium parvum oocysts.
The following pharmaceutical reduction claims have not been certifi ed by NSF International. Claims tested and verifi ed
by independent laboratory:
Contaminant
Reduction
Average Infl uent
Atenolol
Fluoxetine
Ibuprofen
Progesterone
Trimethoprim
Application Guidelines/Water Supply Parameters
Service Flow
Water Supply
It is essential that the manufacturer's recommended installation, maintenance and filter replacement requirements be carried out for the product to perform as advertised.
See Installation Manual for Warranty information.
Note:
While the testing was performed under standard laboratory conditions,
actual performance may vary.
Replacement Cartridge: RPWF. For estimated costs of replacement elements
please call 1-800-626-2002 or visit our website at www.geapplianceparts.com.
WARNING
To reduce the risk associated with ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality
without adequate disinfection before and after the system. Systems certifi ed
for cyst reduction may be used on disinfected water that may contain fi lterable
cysts. EPA Establishment Number 070595-MEX-001.
NOTICE
To reduce the risk associated with property damage due to water leakage:
• Read and follow use instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Do not install if water pressure exceeds 120 psi (827 kPa). If your water pressure
GE
Appliances
Appliance Park
Louisville, KY 40225
geapplianceparts.com
71879_rpwf_insrt_update.indd 2
71879_rpwf_insrt_update.indd 2
Contaminant Reduction Determined by NSF testing.
NSF specifi ed
Challenge Concentration
2.0 mg/L
2.0 mg/L ± 10%
At least 10,000 particles/mL
10
7
to 10
8
fi bers/L; fi bers
109 MFL
greater than 10μm in length
0.009 mg/L
0.009 mg/L ± 10%
0.016 mg/L
0.015 mg/L ± 10%
0.08 mg/L
0.08 mg/L ± 10%
Minimum 50,000 cysts/L
0.140 mg/L
0.15 mg/L ± 10%
0.158 mg/L
0.15 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.006 mg/L
0.006 mg/L ± 10%
0.002 mg/L
0.002 mg/L ± 10%
0.222 mg/L
0.225 mg/L ± 10%
0.015 mg/L
0.015 mg/L ± 10%
0.218 mg/L
0.210 mg/L±10%
0.278 mg/L
0.300 mg/L ± 10%
NSF specifi ed
Challenge Concentration
1088 ng/L
N/A
845 ng/l
N/A
898 ng/L
N/A
945 ng/L
N/A
403 ng/L
N/A
0.5 gpm (1.89 lpm)
Potable Water
Average Product
Max Permissible
Avg %
Water
Product Water
Reduction
Concentration
Concentration
97.4%
0.05 mg/L
N/A
99.0%
71,850 pts/ml
N/A
99.99%
<1 MFL
N/A
94.4%
0.0005 mg/L
0.003 mg/L
96.4%
0.001 mg/L
0.005 mg/L
98.8%
0.001 mg/L
0.04 mg/L
99.99%
3 cyst/L
N/A
99.3%
0.001 mg/L
0.010 mg/L
98.3%
0.002 mg/L
0.010 mg/L
91%
0.0003 mg/L
0.002 mg/L
88.3%%
0.0007 mg/L
0.002 mg/L
99%
0.00002 mg/L
0.0002 mg/L
99.8%
0.0005 mg/L
0.075 mg/L
93.5%
0.001 mg/L
0.003 mg/L
99.9%
0.0001 mg/L
0.07 mg/L
97.7%
0.0015 mg/L
N/A
Avg %
Average Product Water
Reduction
Concentration
99.5%
5.0 ng/L
99.4%
5.0 ng/L
98.8%
9.9 ng/L
99.4%
5.5 ng/L
99.5%
2.0 ng/L
Water Pressure
25-120 psi (172– 827 kPa)
Water Temperature
33º F - 100º F (0.6º C - 38º C)
exceeds 80 psi, you must install a pressure-limiting valve. Contact a plumbing
professional if you are uncertain how to check your water pressure.
• Do not install where water hammer conditions may occur. If water hammer
conditions exist you must install a water hammer arrester. Contact a plumbing
professional if you are uncertain how to check for this condition.
• Do not install on hot water supply lines. The maximum operating water
temperature of this fi lter system is 100º F (38º C).
• Protect fi lter from freezing. Drain fi lter when temperatures drop
below 33ºF (0.6ºC).
• The disposable fi lter cartridge must be replaced every 6 months at the
rated capacity, or sooner if a noticeable reduction in fl ow rate occurs.
For conditions of use, health claims certified by the California Department of Public
Health, and replacements, see performance data sheet. California Department
of Public Health Certification #11-2110. The contaminants or other substances
removed or reduced by this water filter are not necessarily in all users' water.
NSF Reduction
NSF
Requirements
Test Report
≥50%
J-00102044
≥85%
J-00106249
≥99%
J-00102069
N/A
J-00102058
N/A
J-00102065
N/A
J-00102059
≥99.95%
J-00102057
N/A
J-00102052
N/A
J-00102053
N/A
J-00102054
N/A
J-00104087
N/A
J-00102063
N/A
J-00102067
N/A
J-00102061
N/A
J-00102064
≥95%
J-00102070
Max Permissible
Product Water
NSF
Concentration
Test Report
N/A
J-00103221
N/A
J-00103221
N/A
J-00103726
N/A
J-00103727
N/A
J-00103221
System tested and certifi ed by NSF
International against NSF/ANSI Standard
42 and Standard 53 in model GE RPWF
for the reduction of the claims specifi ed
on the performance data sheet.
REPLACEMENT
ELEMENT
34-8708-7119-0
EPA #070595-MEX-001
© 2012 General Electric Company
PC71879
10/17/12 3:33 PM
10/17/12 3:33 PM