Venting Requirements - Maytag MEDC700VJ - 27in Centennial Series Electric Dryer Oxide Installation Instructions Manual

27" (69 cm) electric dryer
Hide thumbs Also See for MEDC700VJ - 27in Centennial Series Electric Dryer Oxide:
Table of Contents

Advertisement

Available languages

Available languages

WARNING
Fire Hazard
Use a heavy metal vent.
Do not use a plastic vent.
Do not use a metal foil vent.
Failure to follow these instructions can result in death
or fire.
WARNING:
To reduce the risk of fire, this dryer MUST BE
EXHAUSTED OUTDOORS.
IMPORTANT: Observe all governing codes and ordinances.
The dryer exhaust must not be connected into any gas vent,
chimney, wall, ceiling, attic, crawlspace, or a concealed space
of a building.
If using an existing vent system
Clean lint from the entire length of the system and make sure
exhaust hood is not plugged with lint.
Replace any plastic or metal foil vent with rigid or flexible
heavy metal vent.
Review Vent system chart. Modify existing vent system if
necessary to achieve the best drying performance.
If this is a new vent system
Vent material
Use a heavy metal vent. Do not use plastic or metal foil vent.
4" (10.2 cm) heavy metal exhaust vent and clamps must be
used. DURASAFE™ venting products are recommended.
4" (10.2 cm) heavy metal exhaust vent
DURASAFE™ vent products can be purchased from your
dealer or by calling the toll-free number listed on the cover
of the Dryer User Instructions. For more information, see
the "Assistance or Service" section of the Dryer User
Instructions.
10

Venting Requirements

4"
10.2 cm
Rigid metal vent
For best drying performance, rigid metal vents are
recommended.
Rigid metal vent is recommended to avoid crushing and
kinking.
Flexible metal vent
Flexible metal vents are acceptable only if accessible for
cleaning.
Flexible metal vent must be fully extended and supported
when the dryer is in its final location.
Remove excess flexible metal vent to avoid sagging and
kinking that may result in reduced airflow and poor
performance.
The total length of flexible metal vent shall not exceed
8 ft (2.4 m).
Do not install flexible metal vent in enclosed walls, ceilings,
or floors.
Elbows
45° elbows provide better airflow than 90° elbows.
Good
Clamps
Use clamps to seal all joints.
The exhaust duct shall not be assembled with screws or
other fastening means that extend into the duct and catch
lint. Do not use duct tape.
Exhaust
Recommended hood styles are shown here.
A
(10.2 cm)
A. Louvered hood style
B. Box hood style
The angled hood style (shown here) is acceptable.
4"
(10.2 cm)
Better
Clamp
B
4"
(10.2 cm)
4"
2½"
(6.4 cm)

Advertisement

Table of Contents
loading

Table of Contents