Setup
If you are not using DHCP, follow the setup instructions in the Cisco Gigabit Ethernet Switch Module for
HP p-Class BladeSystem Software Configuration Guide, to assign the CGESM an IP address. Use a web
browser to access the configuration management and operation features at http://10.10.10.168:80,
where 80 is the default port number.. Use the web interface to disable the cross connection (XConnects)
(ports 17 and 18) and to ensure all ports are in the same VLAN.
Disabling the cross connection ports
With XConnects between Interconnect A and Interconnect B, the multi-path solution may use loops
established at the interconnect switching level. To avoid this, disable the XConnects. Each interconnect
model has different XConnect ports. Some interconnects don't enable these ports by default. The following
procedure assumes the use of CGESM. See the interconnect documentation for more information.
1.
Log in to the first interconnect on the web switch web page at http://10.10.10.168:80.
2.
Click the Configuration link in the left frame of the web
page.(Figure
40).