Fuser Service Check - Lexmark T520 - 20ppm 8MB Par USB Pcl6 Ps3 Ppds Service Manual

Service manual
Hide thumbs Also See for T520 - 20ppm 8MB Par USB Pcl6 Ps3 Ppds:
Table of Contents

Advertisement

4520-xxx

Fuser Service Check

Cold Fuser Service Check
Error codes 920, 921, and 922 may display for a cold fuser failure. A
920 error caused by low line voltage can sometimes be cleared by
turning the machine off and then on again. A 925 service error
indicates the wrong fuser lamp is installed. Be sure the correct type
of fuser lamp is installed in the printer.
If the correct lamp is installed and a 925 error remains, the problem
may be due to the following:
The fuser may have reached standby temperature too quickly.
The line voltage may be above the maximum rating for the
printer.
Note: A 920, 921 or 922 fuser error may be caused by an
incorrectly mounted thermistor.
Service Tip: Set the Fuser Temperature to NORMAL before starting
this service check.
FRU
1
Fuser Lamp (Incorrect
Lamp/925 Service Error)
2-56
Service Manual
Action
Install the correct voltage and
wattage lamp or fuser assembly.
If the correct fuser lamp is installed
and the 925 error remains, the fuser
may have reached standby
temperature too quickly. Check that
the line voltage is not exceeding the
maximum rating for the printer.