Reliability; Formatted Capacities; Programmable Drive Capacity - Seagate Savvio 10K Product Manual

Savvio fc series
Hide thumbs Also See for Savvio 10K:
Table of Contents

Advertisement

3.4

Reliability

• Mean Time Betwen Failures (MTBF) of 1,400,000 hours.
• LSI circuitry
• Balanced low mass rotary voice coil actuator
• Self-Monitoring Analysis and Reporting Technology (S.M.A.R.T.)
• Dithering
• 5-year warranty
3.5

Formatted capacities

Standard OEM models are formatted to 512 bytes per block. The sector size is selectable at format time. Users
having the necessary equipment may modify the data block size before issuing a format command and obtain
different formatted capacities than those listed.
Note.
For 2 gigabit operation, sector sizes must be divisible by 8.
To provide a stable target capacity environment and at the same time provide users with flexibility if they
choose, Seagate recommends product planning in one of two modes:
1. Seagate designs specify capacity points at certain sector sizes that Seagate guarantees current and future
products will meet. We recommend customers use this capacity in their project planning, as it ensures a
stable operating point with backward and forward compatibility from generation to generation. The current
guaranteed operating points for this product are:
ST936701
Sector Size
Decimal
512
71,687,372
514
70,512,692
520
70,197,546
522
68,914,176
524
68,766,592
2. Seagate drives also may be used at the maximum available capacity at a given sector size, but the excess
capacity above the guaranteed level will vary between other drive families and from generation to genera-
tion, depending on how each sector size actually formats out for zone frequencies and splits over servo
bursts. This added capacity potential may range from 0.1 to 1.3 percent above the guaranteed capacities
listed above. Using the drives in this manner gives the absolute maximum capacity potential, but the user
must determine if the extra capacity potential is useful, or whether their assurance of backward and for-
ward compatibility takes precedence.
3.5.1

Programmable drive capacity

Using the Mode Select command, the drive can change its capacity to something less than maximum. See the
Mode Select (6) parameter list table in the Fibre Channel Interface Manual, part number 7767496. Refer to the
Parameter list block descriptor number of blocks field. A value of zero in the number of blocks field indicates
that the drive shall not change the capacity it is currently formatted to have. A number in the number of blocks
field that is less than the maximum number of LBAs changes the total drive capacity to the value in the block
descriptor number of blocks field. A value greater than the maximum number of LBAs is rounded down to the
maximum capacity.
Savvio FC Product Manual, Rev. D
ST973401
Hex
Decimal
445DCCC
143,374,744
433F034
141,025,384
42F212A
140,395,092
41B8C00
137,828,352
4194B80
137,577,184
Hex
88BB998
867E068
85E4254
8371800
83342E0
9

Advertisement