Service And Adjustment; Tank (Sediment) Cleaning; Venting System Inspection; Burner Inspection - Kenmore 33094 - Power Miser 9 Owner's Manual

Ultra low nox gas water heater
Table of Contents

Advertisement

Tank (Sediment)
Cleaning
Burner
inspection
Sediment
build-up
on the tank
bottom
may
create
varying
amount
of noise
and if left in the tank will cause
permanent
tank failure.
In some water areas,
you may not be able to drain
all sediment
deposits
by simply
draining
the tank.
in these
cases
Mag-Erad
(part no. 23600)
can be used to help remove
the sediment
deposits.
This
may be ordered
from the Sears
Service
Center.
For ordering,
refer
to the Parts
Order
List
section.
Flood
damage
to a water
heater
may not be readily
visible
or
immediately
detectable.
However,
over a period
of time a flooded
water
heater
will create
dangerous
conditions
which can cause
DEATH, SERIOUS
BODILY INJURY, OR PROPERTY
DAMAGE.
Contact
a Sears
Service
Center
to replace
a flooded
water
heater.
Do not attempt
to repair
the unit[ It must be replaced[
At least once
a year a visual
inspection
should
be made
of the
main burner.
See Figure
23.
Vent System
Inspection
Carbon
Monoxide
and Fire Hazard
, Flue gases may escape
if vent pipe
is not connected
, Be ale_ for obstructed,
sooted
or
_'>"-:;
de_erbrated
vent system
to avoid
}1 {_1:
serious
njury
or death.
• Do _ot store corrosive
chemicals
in the vicinity
of water
heater
• Chemic!
corrosion
o_ flue and vent
system
can cause serious
injury of
death,
Breathing
cadxm
monoxide
can cause brain
damage
or
death. A_ways read and understand
instruct:ion
manual
CORRECT
FLAME
SOFT
BLUE
FIGURE 23,
Inspect
burner
flames
through
viewport.
Flames
should
be very
small with a blue haze and small amounts
of yellow
or orange
at
the edges.
After several
minutes
of operation
the burner
screen
may glow
red. If large flames
are observed
at anytime
shut-off
unit and contact
a Sears
Service
Center.
At least once
a year a visual
inspection
should
be made of the
venting
system.
You should
look for:
Obstructions
which
could
cause
improper
venting.
The
combustion
and ventilation
air flow must not be obstructed.
Damage
or deterioration
which could cause improper
venting
or leakage
of combustion
products.
Rusted
flakes
around
top of water
heater.
Be sure
the vent
piping
is properly
connected
to prevent
escape
of dangerous
flue
gasses
which
could
cause
deadly
asphyxiation.
Obstructions
and deteriorated
vent systems
may present
serious
health
risk or asphyxiation.
Chemical
vapor corrosion
of the flue and vent system
may occur
if air for combustion
contains
certain chemical
vapors.
Spray can
propellants,
cleaning
solvents,
refrigerator
and air conditioner
refrigerants,
swimming
pool
chemicals,
calcium
and sodium
chloride,
waxes,
bleach
and process
chemicals
are typical
compounds
which
are potentially
corrosive.
If when
inspecting
the
vent
system
you
find
sooting
or
deterioration,
something
is wrong.
Call the local gas supplier
to
correct
the problem
and clean
or replace
the flue and venting
before
resuming
operation
of the water
heater.
2O