Fit T &Pvalve insulation over v alve. Make s ure that t he insulation
does notinterfere withthelever o ftheT&Pvalve.
Secure a llinsulation using tape.
Temperature-Pressure
Relief Valve
Explosion
Hazard
- Temperature-pressure
relief valve
must comply
with ANSI Z21.22
and ASME code.
- Properly
sized
temperature-
pressure
relief
valve
must
be
installed in opening provided.
-Can
result
in overheating
arid
e×cessive tank pressure.
- Can cause serious inJury or death.
This heater
is provided
with a properly
certified
combination
temperature
- pressure
relief valve by the manufacturer.
The valve is certified
by a nationally
recognized
testing
laboratory
that
maintains
periodic
inspection
of production
of listed
equipment
as meeting
the requirements
for Relief Valves for Hot
Water Supply
Systems,
ANSI Z21.22
and the code requirements
of ASME.
If replaced,
the valve must meet the requirements
of local codes,
but not less than a combination
temperature
and pressure
relief
valve certified
as indicated
in the above
paragraph.
The valve
must be marked
with a maximum
set pressure
not to
exceed
the marked
hydrostatic
working
pressure
of the water
heater
(150 psi = 1,035kPa)
and a discharge
capacity
not less
than the water
heater
input
rate as shown
on the model
rating
plate.
For safe operation
of the water heater,
the relief valve
must not
be removed
from its designated
opening
nor plugged.
The temperature-pressure
relief valve
must be installed
directly
into the fitting
of the water
heater designed
for the relief valve.
Position
the valve
downward
and provide
tubing
so that
any
discharge
will exit only
within
6 inches
(153
mm)
above,
or
at any distance
below
the structural
floor,
see Figure
16.
Be
certain
that no contact
is made
with
any live
electrical
part.
The
discharge
opening
must
not be blocked
or reduced
in
size under
any circumstances.
Excessive
length,
over
30 feet
(9.14 m), or use of more than four elbows
can cause restriction
and reduce
the discharge
capacity
of the valve.
No valve
or other obstruction
is to be placed
between
the relief
valve and the tank.
Do not connect
tubing
directly
to discharge
drain
unless
a 6 inch air gap is provided.
To prevent
bodily
injury, hazard
to life, or property
damage,
the relief valve
must
be allowed to discharge
water in quantities
should circumstances
demand.
If the discharge
pipe is not connected
to a drain or other
suitable
means,
the water
flow may cause
property
damage.
HOT WATER
COLD WATER
OUTLET
INLET
SHUTOFF
VALVE
HOT
_S_
\
TEMPERATURE
- PRESSURE
RELI EF VALVE
(OPTIONAL
TOP T&P RELIEF
VALVE NOT SHOWN)
_---DISCHARGE
PIPE
(Do not cap or plug)
FIGURE 16.
Water
Damage
Hazard
. Temperature-pressure
relief valve discharge
pipe must terminate at adequate drain.
The Discharge Pipe:
• Shall not be smaller in size than the outlet pipe size of the
valve, or have any reducing couplings or other restrictions.
• Shall not be plugged or blocked.
• Shall be of material listed for hot water distribution.
• Shall be installed so as to allow complete drainage of both
the temperature-pressure
relief valve, and the discharge
pipe.
• Shall terminate at an adequate drain.
• Shall not have any valve between the relief valve and tank.
Water
temperature
over
t25°F
(52°C) can cause severe burns
instantly resulting in severe injury
or death.
Children,
the
elderly,
and the
physically
or mentally
disabled
are at highest risk for scald injury,
Feel
water
before
bathing
or
showering.
Temperature
limiting valves are
available.
Read instruction
manual for safe
temperature setting
14