o Before
removing
any
access
panels
or servicing
the water
heater, make sure the electrical
supply
to the water
heater
is
turned "OFF".
• Failure to do this could result in
death,
serious
bodily
injury,
or
property damage.
1.
Before
beginning
turn "OFF" the electric
power supply
to the
water
heater.
FIGURE 30.
2. Turn off the water
supply
to the water
heater
at the water
Shut-off
valve or water
meter.
FIGURE 3t.
3. Attach
a hose to the water
heater
drain
valve
and put the
other end in a floor drain or outdoors.
Open the water
heater
drain valve.
Open a nearby
hot water faucet which will relieve
pressure
in the water
heater
and speed
draining.
4. Remove
the two screws
securing
the access
panel,
and
remove
panel.
FIGURE 33.
5.
Remove
the insulation
cap with handle.
IQ
FIGURE 34.
6. Lift out the tab as shown to unclip
the terminal
cover from the
thermostat.
The terminal
cover can now be removed
from the
thermostat.
LiFT OUT TAB TO UNCLIP
TERMINAL
COVER
FROM THERMOSTAT
LOWER THERMOSTAT
WITHOUT HiGH LiMiT
FIGURE 32.
* Burn hazard
, Hotwater
discharge.
, Keep hands clear of drain
valve discharge.
UPPER AND LOWER
THERMOSTAT
WITH
HIGH LIMIT
FIGURE 35.
Disconnect
the two wires
on the element
and unscrew
the
old element
from the tank.
The water
passing
out of the drain valve
may be extremely
hot.
To avoid being scalded,
make sure all connections
are tight and
that the water
flow is directed
away from any person.
2O