Kenmore 32154 - Power Miser 12 Owner's Manual page 14

Electric water heater
Table of Contents

Advertisement

11.Replace theaccess p anel.
FIGURE 21.
12. Complete
wiring
to the water
heater,
or if completed,
turn
"ON" electric
power to the water
heater after filling the tank
with water.
%.
FIGURE 22,
improper
installation
and use may result
in property
damage.
. Fill tank with water
before operation.
Never
use this water
heater
unless
it is completely
full of water.
To prevent
damage
to the tank and heating
element,
the tank
must
be filled
with water.
Water
must flow
from the hot water
faucet
before
turning
"ON" power.
You must
provide
all wiring
of the proper
size outside
of the
water
heater. You must obey local codes
and electric
company
requirements
when you install this wiring.
If you are not familiar
with electric
codes and practices,
or if you
have any doubt, even the slightest doubt,
in your ability to connect
the wiring
to this water
heater, obtain the service
of a competent
electrician.
Contact
your
Sears
salesperson
to arrange
for a
professional
electrician.
WATER
HEATERS
EQUIPPED
FOR
ONE
VOLTAGE
ONLY:
This water
heater
is equipped
for one type voltage
only. Check
the rating
plate
near
the bottom
access
panel
for the correct
voltage.
DO NOT use this water
heater
with any voltage
other
than the one shown
on the model
rating plate.
Failure to use the
correct
voltage
can cause problems
which can result in DEATH,
SERIOUS
BODILY
INJURY,
OR PROPERTY
DAMAGE.
If you
have any questions
or doubts
consult
your electric
company.
Fire Hazard / Electric
Shock
Hazard
®
Do not use this water heater with
any voltage other than shown on the
model rating plate.
Failure
to use the correct
voltage
shown
on the
model
rating
plate
could result in death,
serious
bodily
injury, or property
damage.
I4
If wiring
from your fuse box or circuit
breaker
box was aluminum
for your old water heater,
replace
it with copper
wire. If you wish
to reuse the existing
aluminum
wire, have the connection
at the
water
heater
made
by a competent
electrician.
Contact
your
Sears salesperson
to arrange
for a professional
electrician.
Provide
a way
to easily
shut
off the electric
power
when
working
on the water
heater.
This
could
be with
a circuit
breaker
or fuse
block
in the entrance
box
or a separate
disconnect
switch.
Install
and connect
a circuit
directly
from
the main fuse
or
circuit
breaker
box. This
circuit
must
be the right
size
and
have its own fuse or circuit
breaker.
Refer to the chart
in the
"Product
Specifications"
section
for the correct
size wire and
fuse or circuit
breaker.
3. If metal
conduit
is used for the grounding
conductor:
a.
The
grounding
electrode
conductor
shall
be of copper,
aluminum,
or copperclad
aluminum.
The
material
shall
be of one continuous
length
without
a splice
or
joint.
b.
Rigid
metal
conduit,
intermediate
metal
conduit,
or
electrical
metallic
tubing
may be used for the grounding
means if conduit
or tubing is terminated
in fittings approved
for grounding.
c.
Flexible
metal
conduit
or flexible
metallic
tubing
shall be
permitted
for grounding
if all the following
conditions
are
met:
The length
in any ground
return
path does not exceed
6
feet.
The circuit conductors
contained
therein
are protected
by
overcurrent
devices
rated at 20 amperes
or less.
The conduit
or tubing
is terminated
in fittings
approved
for
grounding.
For complete
grounding
details
and all allowable
exceptions,
refer to the current
edition
of the NEC - National
Electrical
Code
NFPA 70.
4. Astandard
1/2" conduit
opening
has been made
in the water
heater junction
box for the conduit
connection.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents