A.O. Smith SGS - 100 Installation & Service Manual page 16

A.o. smith gas water heater installation user and service manual
Table of Contents

Advertisement

2
2.4.2
Protection
Against frost:
- T
< 5°C
1
- T
< 5°C
2
For maximum water temperature:
- T
> 85°C
1
- T
> 85°C
2
For extra safety:
- T
> 93°C
1
- T
> 93°C
2
2.4.3
Protection
Against frost:
- S
, S
< 5°C
2
3
For maximum water temperature:
- S
, S
> 85°C
2
3
For extra safety:
- S
, S
> 93°C
2
3
2.4.4
2.4.5
16
Working principle of the appliance
Appliance water temperature protection
The electronic controller uses temperature sensors T
several temperatures that are important for safety.
The table explains the functioning of these temperature sensors.
Temperature protection
Description
The frost protection cuts in. The water is heated to 20°C.
The high-limit safeguard serves to prevent overheating and/or excessive
formation of scale in the appliance. If the high-limit safeguard is activated, the
heating is stopped. This causes the water in the tank to cool down. Once the
water has cooled sufficiently (T
appliance.
A lockout error of the water heater controller takes place. The controller must
be manually reset before the appliance can resume operation
conditions"). The reset may only be performed if T
Water temperature protection for the storage tank
Using temperature sensors S
monitors several temperatures in the storage tank that are related to safety.
Temperature protection
Description
The frost protection cuts in. The water is heated to 20°C.
The high-limit safeguard serves to prevent overheating and/or excessive
formation of scale in the storage tank. If the high-limit safeguard is activated,
the heating is stopped. This causes the water in the storage tank to cool down.
Once the water has cooled sufficiently (S
resets the appliance.
A lockout error of the water heater controller takes place. The controller must
be manually reset before the appliance can resume operation
conditions"). The reset may only be performed if S
Gas valve
The electronic controller opens the gas valve so that gas can be supplied to the
burner. As a safety measure, the gas valve has a double shut-off. The double
shut-off guarantees complete isolation of the appliance from the gas supply.
To help ensure smooth ignition, the gas valve opens gradually ('softlite").
Fan
The fan (18) provides an optimum air supply when there is a heat demand. As
a safety feature, the fan ensures that any gases present in the combustion
chamber are removed, both before and after combustion. We refer to this as
pre- and post-purge.
The fan speed is continuously monitored by the electronic controller (4). The
electronic controller takes control if the speed of rotation varies too much from
the set value.
(7) and T
1
< 78°C), the electronic controller resets the
1
<78°C.
1
and S
, the solar heating system controller
2
3
< 78°C), the electronic controller
3
< 78°C.
3
Instruction manual SGS
gis
to monitor
2
(8.4 "Error
(8.4 "Error

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgs-80

Table of Contents