Download Print this page

A.O. Smith Series 200 Specification Sheet page 2

Promax plus high efficiency gas water heaters specification sheet 200 series 201 series
Hide thumbs Also See for Series 200:

Advertisement

FIRST
ENERGY
MODEL
HOUR
SERIES
NUMBER
RATING
FACTOR
GALLONS
TALL MODELS
GVR-30
200/201
67
.62
GVR-40
200/201
70
.62
GVR-50
88
200/201
.62
SHORT MODEL
GVRL-40
202/203
67
.62
Recovery capacity based on actual performance tests.
Water Connections – 3/4" on all models.
† Propane Gas – 37,000 BTU input for 50 gallon models, 36,000 BTU for 40 gallon models and 32,000 BTU input for 30 gallon models.
For 10-Year Tank and 6-Year Parts Warranty, change "G" to "X" in Model Number (example: XVR-40).
Heat Trap Nipples installed on all models.
All Models are ENERGY STAR
®
qualified.
Flammable Vapor Ignition
Resistant Water Heaters
A. O. Smith FVIR design meets or exceeds the American National Standards Institute standards
(ANSI Z21.10.1 - 4.1 CSA Standards) that deal with the accidental or unintended ignition of
flammable vapors, such as those emitted by gasoline.
Feature a sealed combustion chamber with air intake filter and a flame arrestor built
into the water heater base. In addition, a thermal cutoff (TCO) device, is designed
to shut off gas flow to the burner and pilot if poor combustion is detected.
If flammable vapors accidentally enter the
combustion chamber, the arrestor is designed
so flames burn off the top surface and can not
escape down through the arrestor.
For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith Corporation reserves the right to make produ ct changes or improvements without prior notice.
June 2010R
www.hotwater.com
Residential Gas Water Heaters
®
BTU
RECOVERY
GALLON
INPUT
90ºF RISE
CAPACITY
PER HOUR
GALLONS
NATURAL
PER HOUR
30
35,500
36
40
40,000
41
40,000
50
41
40
40,000
41
DIMENSIONS IN INCHES
FOAM
THICKNESS
A
B
C
(INCHES)
2
61-1/2
58
18
2
61-3/4
58-1/4
20
57-1/4
2
61
22
2
51-1/2
47-3/4
22
ANODE ROD*
A. Industry standard thermocouple
B. Large View Port for easy burner inspection
C. 360
D. Thermal Cutoff (TCO) with manual reset
SERIES 200/201
DRAFT
HOOD
D
E
F
OUTLET
13
8
3 or 4
52
13
8
3 or 4
51-3/4
13
50-1/4
8
3 or 4
13
41
3 or 4
8
HOT
CONNECTION
E
C
T&P VALVE
1/2" GAS
CONNECTION
D
*Location for optional top-mounted
T&P Valve if ordered from factory.
Maximum Hydrostatic Working Pressure: 150 PSI.
0
combustion air filter
APPROXIMATE
SHIPPING
WEIGHT
(LBS)
126
150
165
147
COLD
CONNECTION
A
B
F
Page 2 of 2
AOSRG45350

Advertisement

loading

This manual is also suitable for:

Series 201Gvr-30Gvr-40Gvr-50Gvrl-40