Schedule Write - NEC MultiSync X461UNV Manual

Hide thumbs Also See for MultiSync X461UNV:
Table of Contents

Advertisement

FL: Option
P MODE: Picture mode
ETX (03h): End of Message
Check code
BCC: Block Check Code
Refer to the section 4.5 "Check code" for a BCC calculation.
Delimiter
CR (0Dh): End of packet

10.2 Schedule Write

This command is used in order to write the setting of the Schedule.
1) The controller requests the monitor to write Schedule.
Header
SOH-'0'-Monitor ID-'0'-'A'-'1'-'8'
Header
SOH (01h): Start Of Header
'0' (30h): Reserved
Monitor ID: Specify the Monitor ID of which you want to change a setting.
'0' (30h): Message sender is the controller.
'A' (41h): Message type is "Command".
'1'-'8'(31h, 38h): Message length.
Message
STX (02h): Start of Message
'C'-'2'-'1'-'4' (43h, 32h, 31h, 34h): Schedule writes command
PG-ON HOURS-ON MIN-OFF HOURS-OFF MIN-INPUT-WD-FL-P MODE: Schedule data
PG: Program No.
ON_HOUR: Turn on time (hour)
bit 2: Wednesday
bit 3: Thursday
bit 4: Friday
bit 5: Saturday
bit 6: Sunday
EX.
'0'-'1'(30h, 31h): Monday
'0'-'4'(30h, 34h): Wednesday
'0'-'F'(30h, 46h): Monday, Tuesday, Wednesday and Thursday
'7'-'F'(37h, 46h): Monday to Sunday
bit 0: 0:once 1:Everyday
bit 1: 0:once 1:Every week
bit 2: 0:Disable 1:Enable
EX.
'0'-'1'(30h, 31h): Disable, Everyday
'0'-'4'(30h, 34h): Enable, once
'0'-'0'(30h, 30h): HI_BRIGHT
'0'-'1'(30h, 31h): STANDARD
'0'-'2'(30h, 32h): sRGB
'0'-'3'(30h, 33h): CINEMA
'0'-'4'(30h, 34h): ISF_DAY
'0'-'5'(30h, 35h): ISF_NIGHT
'0'-'6'(30h, 36h): AMBIENT_1
'0'-'7'(30h, 37h): AMBIENT_2
STX-'C'-'2'-'1'-'4'-PG-ON HOUR-ON MIN-
OFF HOUR-OFF MIN-INPUT-WD-FL-P MODE-ETX
Ex.) If Monitor ID is '1', specify 'A'.
'0'-'0'(30h, 30h): Program No.1
|
'0'-'6'(30h, 36h): Program No.7
Message
(25/43)
Check code
Delimiter
BCC
CR