Jumper Settings - Epson C82303/09 (Parallel I/F User Manual

32kb parallel interface
Table of Contents

Advertisement

Jumper settings

The tables below give you information about the interface
conditions that can be selected using jumpers. In all cases, ON
denotes the connection of the jumper (covering both termi-
nals), while OFF denotes the disconnection of the jumper.
Table 2. Jumper settings
Jumper
J1
ON: SLCT IN signal is enable. (See Note 1.)
12
Fixed (See Note 2.)
Fixed (See Note 2.)
J3
A
Data latch liming
B
JG
ON: Connect Chassis Ground to Signal Ground.
Note
1.
SLCT IN signal can be fixed LOW by setting the printer
DIP switch , jumper or SelecType function. If this signal is
fixed Low, you should not connect J1. When J1 is ON,
SLCT IN signal (pin No. 36 of I/F connector on the I/F
board) is connected to the printer through the I/F board to
enable it to be controlled by a Host computer. Sampling
this signal is always carried out by the printer, therefore
this function depends on the printer specification.
2.
J2 and J3 jumpers are connected at the factory, and you
should not change these setting.
Function
See Table 3.
selection.
Factory Setting
OFF
-
-
OFF
I