Warning Indicators; Self-Diagnosis Display - Sony HVRMRC1K - Mem Recording Unit Operating Instructions Manual

Memory recording unit
Hide thumbs Also See for HVRMRC1K - Mem Recording Unit:
Table of Contents

Advertisement

Warning indicators

Self-diagnosis display

When an error occurs the following warning indicators may appear on the LCD screen.
Message
A:ss:ss/I:ss:ss/P:ss:ss/
M:ss:ss/F:ss:ss/X:ss:ss
(Self-diagnosis display)
24
Cause/Corrective Action
If an error recurs after you repeat corrective action several times, contact Sony
Customer Service or the place of purchase.
A:12:s
• CompactFlash-related error has occurred.
t Transfer speed of the CompactFlash may be slow. Be sure that the
CompactFlash you are using is the recommended type.
A:19:s
• The CompactFlash you are using is not recognized.
t Check the type you are using.
I:12:s
• Internal error has occurred.
t Turn this unit off and then back on.
P:12:s
• Internal error has occurred.
t Turn this unit off and then back on.
P:21:s
• Internal error has occurred.
t Turn this unit off and then back on.
M:21:s
• Recorded image was not processed correctly.
t Turn this unit off and then back on.
F:11:s
• Internal error has occurred.
t Turn this unit off and then back on.
F:12:s
• There is a conflict in the CompactFlash logic structure.
t Move the required data to the computer and reformat the CompactFlash using
this unit.
F:21:s
• Internal error has occurred.
t Turn this unit off and then back on.
F:22:s
• Internal error has occurred.
t Turn this unit off and then back on.
F:29:s
• Firmware is not recorded.
F:91:s
• Internal error has occurred.
t Turn this unit off and then back on.
F:92:s
• Internal error has occurred.
t Turn this unit off and then back on.
X:91:s
• Internal error has occurred.
t Turn this unit off and then back on.
X:99:s
• Internal error has occurred.
t Turn this unit off and then back on.