Download Print this page
Electrolux EI23SS55H - 25.1 cu. Ft. Refrigerator Service Data Sheet
Electrolux EI23SS55H - 25.1 cu. Ft. Refrigerator Service Data Sheet

Electrolux EI23SS55H - 25.1 cu. Ft. Refrigerator Service Data Sheet

Ice & water - automatic defrost side by side - r134a
Hide thumbs Also See for EI23SS55H - 25.1 cu. Ft. Refrigerator:

Advertisement

PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT
CONTROL SETTING
65°F (18°C) Ambient
Type A with Run/Start
Capacitor
Variable Speed
Standard
Operating Time
74 to 84%
32 to 40%
-2° to 2° F
0° to 4° F
Freezer Temperature
-19° to -17° C
-18° to -16° C
34° to 39° F
34° to 39° F
Refrigerator Temperature
1° to 4° C
1° to 4° C
Low Side Pressure
5 to 12 psig
5 to 12 psig
(cut-in)
43 to 83 kPa
43 to 83 kPa
Low Side Pressure
-2 to 2 psig
-2 to 2 psig
(cut-out)
-14 to 14 kPa
-14 to 14 kPa
High Side Pressure
90 to 105 psig
90 to 115 psig
(last 1/3 cycle)
621 to 724 kPa
621 to 793 kPa
Wattage (last 1/3 cycle)
60 to 65
120 to 150
Amps (running)
.7 to 1.1
1.0 to 1.4
Base Voltage
115 vac (127 vac max)
deFrOst speciFicatiOns
thermostat
Cabinet Size
Cut-in
Cut-out
23', 23' CD, 26'
25° F (-4° C)
47° F (8° C)
Electronic Timer - (ADC) Defrost 24 minutes every 6-96 hours of compressor run time.
cOndenser Fan MOtOr
Watts
rpM
3.1
1100 CW Opposite Shaft
ice MaKer speciFicatiOns
Electrical
115 vac (127 vac max)
Thermostat
Opens at 48° F ( 9° C), Closes at 15° F ( -9° C)
Heater Voltage
85 vac
ice MaKer cOnnectOr pLUG cOnnectiOns
Wire number
Wire color
1
Green/Yellow
2
Yellow
3
Black
4
Light Blue
iMpOrtant: pLease retUrn this sheet tO
it's OriGinaL LOcatiOn
service data sheet
ice & Water - aUtOMatic deFrOst
90°F (32°C) Ambient
Variable Speed
Standard
100%
55 to 65%
-1° to 3° F
-1° to 3° F
iMpOrtant saFetY nOte
-18° to -16° C
-18° to -16° C
34° to 39° F
34° to 39° F
The information provided herein is designed to assist qualified
1° to 4° C
1° to 4° C
repair personnel only. Untrained persons should not attempt to
5 to 12 psig
N/A
43 to 83 kPa
make repairs due to the possibility of electrical shock. Disconnect
-2 to 2 psig
-2 to 2 psig
power cord before servicing this appliance.
-14 to 14 kPa
-14 to 14 kPa
120 to 135 psig
130 to 155 psig
iMpOrtant
827 to 931 kPa
896 to 1069 kPa
If any green grounding wires are removed during servicing,
65 to 80
130 to 160
they must be returned to their original position and properly
.9 to 1.3
1.1 to 1.5
secured.
heater
Watts
Ohms
caUtiOn
450
30
all electrical parts and wiring must be shielded from torch
flame. dO nOt allow torch to touch insulation; it will char
amps
at 200°F and flash ignite (burn) at 500°F. excessive heat will
0.03 Running
distort the plastic liner.
nOte
This product comes equipped with an Adaptive Defrost Control
(ADC). To activate manual defrost, simultaneously press and
connects to:
hold the Fresh Food up (+) and Fresh Food down (-) keys for 5
Ground
seconds. A "d" in the freezer temperature window and "F" in the
Water Valve
refrigerator temperature window will display when the heater is
Line
activated. To deactivate manual defrost, simultaneously press
Neutral
and hold the Fresh Food up (+) and Fresh Food down (-) keys
for 5 seconds. A "d" and "F" will be displayed until the defrost
cycle is complete.
241868703
side BY side - r134a
ice maker information
test cycling
Press the momemtary contact on the ON/OFF switch
for approximately 15 seconds. Ice maker will continue to
complete the cycle.
Water Fill volume
Remove cover by inserting screwdriver in notch at bottom and
prying cover from housing. The water fill adjustment screw
will change the fill time. One turn is equal to 20cc (.68 oz.).
The correct fill is 102 to 110cc (3.25 to 3.5 oz.). When a water
valve is replaced, the fill volume must be checked.
Water Fill
Adjustment
Motor
Gear
Mounting
Plate
Screws
Mounting
Plate
Screw
Timing
Gear
Ice Maker
ON/OFF
Switch

Advertisement

loading

Summary of Contents for Electrolux EI23SS55H - 25.1 cu. Ft. Refrigerator

  • Page 1 ice maker information service data sheet test cycling 241868703 Press the momemtary contact on the ON/OFF switch PERFORMANCE DATA NO LOAD & NO DOOR OPENINGS AT MID-POINT ice & Water - aUtOMatic deFrOst for approximately 15 seconds. Ice maker will continue to CONTROL SETTING side BY side - r134a 65°F (18°C) Ambient...