Advertisement

Owner's Manual
13024800 REV C
06/2010

Advertisement

Table of Contents
loading

Summary of Contents for Hayward Spa Heaters

  • Page 1 Owner’s Manual 13024800 REV C 06/2010...
  • Page 3: Table Of Contents

    Electrical Connections Wiring Diagram Service Analyzer Control Operation Caring for your Pool Heater Initial Startup Meaning of Display Codes Troubleshooting Requesting Assistance or Service Maintenance Winterizing Hayward Heat Pump Pool Heater Limited Warranty ® International Warranty Warranty Card Registration OWnER’S MAnUAL...
  • Page 4: Introduction

    Compared to other types of pool heaters, such as gas or oil-fired, the HAYWARD pool heat pump has a lower heating capacity on a BTU/hr basis. Therefore, it needs to operate for a longer time to accomplish the desired results.
  • Page 5 Please read carefully Record your model’s information Please complete and mail in the ownership registration card provided with this guide. The return address is displayed on the front of your registration card. Simply mail it as you would a postcard. The card helps us notify you about any new information about your heater.
  • Page 6: General Safety Instructions

    General Safety Instructions We care for our customers We have provided important safety messages in this manual and on your heater. Always read and obey all safety messages. IMPORTANT The IMPORTAnT sign calls attention to a note that provides important information or information essential to the completion of a task.
  • Page 7 CAUTION All electrical connections must be done by a qualified electrician and according to the local electrical codes. Always cut off the unit’s main power whenever the access panel is open or removed. Always install the machine outdoors (unless otherwise approved by the manufacturer), while respecting the minimal clearances needed for proper operation and heating.
  • Page 8: Installation Instructions

    Installation Instructions ATTENTION!!! CONSUMER KIT LOCATED BEHIND FRONT PANEL Location The placement of the pool heater is very important in keeping installation costs to a minimum while providing for maximum efficiency of operation, as well as allowing adequate access for service and maintenance. The pool heat pump is designed for outdoor installation and should not be installed in a fully enclosed area, such as a shed, garage, etc.
  • Page 9: Water Piping

    Water piping IMPORTANT The piping sequence is as follows: pool > pool pump > filter > heater > check valve > chemical feeder > pool. Automated chlorine distribution systems, if used, must be placed downstream of the heater to minimize harm to the pool equipment.
  • Page 10: Bonding

    Bonding CAUTION Because all metals have different electrical potentials, all metal and electrical components of the pool system must be bonded together. This includes the metal framework of the pool, the light, the pump, the filter (if made out of metal), the heater, any automatic chlorine generator, and any other metal or electrical equipment.
  • Page 11 Bonding and Plumbing diagram Fig. 2 Chemical feeder Heat Pump Fig. 3 OWnER’S MAnUAL...
  • Page 12: Installation In Combination With Solar Or Gas Heaters

    Solar or Gas Heaters If you are installing a heat pump in combination with any other type of heating device, please call the HAYWARD service department at (908) 355-7995. We will advise you of installation practices that will help keep your warranty valid.
  • Page 13: Using An External Controller

    Using an External Controller To connect the electronic board in order to control it remotely, use the P_S terminals on the right side of the board. next, access the P_S menu and se- lect the desired mode. In internal mode, POOL or SPA mode can be adjusted by using this menu.
  • Page 14: Electrical Connections

    Electrical Connections WARNING The installation of the pool heater should be performed by a certified electrician. To connect the electricity, you must unscrew the five screws of the front panel, then slide the electric cable through the knock out located on the left or the right side of the base, and then insert it in the control box.
  • Page 15: Wiring Diagram

    Wiring Diagram COMPRESSOR COMPRESSOR OWnER’S MAnUAL...
  • Page 16: Service Analyzer Control

    Service Analyzer Control The control panel is factory set to display the temperature in Fahrenheit degrees. Celsius or Fahrenheit mode Heating mode Compressor ( ) Temperature or fan ( ) running and parameter display Heating mode To raise the desired temperature or to Access to change parameters...
  • Page 17: Operation

    Operation To increase the temperature Push the SET key until you see POL or SPA. The programmed temperature will be displayed. Press the UP arrow to increase the temperature setting one degree at a time. To lower the temperature Proceed as explained above using the down arrow To select the pool or spa mode The unit can keep two temperature settings in memory: one for pool mode (max: 95°F/35°C), and the other for spa mode (max: 104°F/40°C).
  • Page 18: Caring For Your Pool Heater

    Caring for your Pool Heater How to protect your pool heater OWnER’S MAnUAL...
  • Page 19: Initial Startup

    Initial Startup IMPORTANT Before starting the pool heater for the first time, it is important to verify that the breaker is in the On position. Also make sure that the water circulates freely and that the pool pump is activited. Then, you will need to set the water temperature you desire.
  • Page 20: Meaning Of Display Codes

    Meaning of Display Codes Service Analyzer Codes Most problems will be detected by the service analyzer and a code will be displayed on the digital display of your heater. Display Meaning of codes The desired programmed temperature point is lower than 60°F (15°C).
  • Page 21: Troubleshooting

    Troubleshooting The pool heater is not running. Heat pump control set to OFF. Raise temperature set point above 60°F (15°C). Desired water temperature Unit will automatically restart is reached. when the water temperature goes below the set point. Main breaker is tripped. Reset main breaker and restart heat pump.
  • Page 22 There is no display and the fan is not running, but the compressor is running. Ask your electrician to verify your heat pump’s power supply by checking over the L1 and L2 connections in the unit’s service box. There is water around the unit. While your pool heater is in the To check if the water really is a heating mode, a large quantity...
  • Page 23: Requesting Assistance Or Service

    Requesting Assistance or Service IMPORTANT All service will be handled by an Authorized Service Center. Warranty may be voided if service is not done by an Authorized Service Representative. Do not return the heater to your dealer as they do not provide service. Before calling for assistance or service, please check the “Troubleshooting”...
  • Page 24: Maintenance

    Maintenance Dirt can accumulate on the evaporator. You can easily remove it by using a non-pressured water spray without damaging the small aluminum fins. The cleaning of the plastic cabinet can be done with the help of a brush and soap. Winterizing First, you must turn the breaker off.
  • Page 25: Hayward ® Heat Pump Pool Heater Limited Warranty

    ® Limited Warranty The HAYWARD heat pump pool heater is warranted to be free of defects in materials and workmanship for a period of two (2) years for parts and (1) one year for labor. In the state of Florida, warranty labor is covered for (2) years.
  • Page 26: International Warranty

    International Warranty The HAYWARD heat pump pool heater is warranted to be free of defects in materials and workmanship for a period of one (1) year. The compressor is warranted for two (2) years, and the titanium tube component of the heat ex- changer has a ten (10) year warranty.

Table of Contents