Vstatic Load Test -Ver0.92 - Biostar M7 VKQ Engineering Validation Test Report

M7vkq compatibility test report
Hide thumbs Also See for M7 VKQ:
Table of Contents

Advertisement

M/B
VID Setting
Electronic Loading
O.C.P test
Over 60A Pass/Fail
Vcore
Vcore
PWM
Loading
Voltage
Input
0A
1.78
11.97
30A
1.73
32A
1.72
12.14
34A
1.72
12.07
36A
1.71
12.05
38A
1.71
12.06
40A
1.71
12.04
42A
1.7
44A
1.69
12.17
46A
1.69
12.18
Comments:
77
V
STATIC LOAD TEST -Ver0.92
CORE
Test Environment
VKQ/0.92
1.75V
Chroma 63030
5V ATX
Connector
5.11
12.2
4.89
4.83
4.67
4.62
4.59
4.52
12.1
4.55
4.59
4.56
Power Supply
Engineer Signature
Pass
O.V.P test 2.02V
AGP Slot
PCI Slot
3.3V
5V
3.3V
3.37
3.3
3.27
3.1
3.09
3.09
3.02
3.07
3.13
3.11
ST-301HR
Pass/Fail
Temperature
MOS(℃)
5V
5.11
32.5
4.87
90.4
4.64
100.6
4.61
111.1
4.61
121.1
4.59
132.4
4.51
143.9
4.53
156.8
4.58
172
4.54
189.5
Pass
Board(℃)
33.4
84
96.7
104.6
114.6
123.1
131.7
138.4
146.1
163.5

Advertisement