Biostar M7TTB Datasheet page 47

Engineering validation test report
Hide thumbs Also See for M7TTB:
Table of Contents

Advertisement

Blue cells need to be filled in with lab measurement
Yellow cells need to have the overall design tolerance entered
VID:
Tolerance:
+Tolerance
- Tolerance
Vdmm
Vscope
Vfb_nl
Vfb_nf
Static Voltage Measurements at pins AC14/AC15
Current
0
10
20
30
40
50
60
Ripple Voltage Measurements (mV) at pins AC14/AC15
Current
0
10
20
30
40
50
60
Load Step
0A to 0A
0A to 10A
0A to 20A
0A to 30A
0A to 40A
0A to 50A
0A to 60A
47
1.453
1.457
1.457
Measured Static Voltage
1.453
1.439
1.424
1.410
1.394
1.378
1.374
Measurement
2.800
4.000
4.400
5.200
6.000
6.600
4.000
Transient Min (mV) at pins AC14/AC15
Current
0
10
20
30
40
50
60
1.475V
1.00%Overall
0.007V
0.007V
V
V
V
V
Units
V
V
V
V
V
V
V
Units
mV
mV
mV
mV
mV
mV
mV
Measurement
0.00
24.40
38.00
58.00
78.00
95.00
111.00
Units
mV
mV
mV
mV
mV
mV
mV

Advertisement

Table of Contents
loading

Table of Contents