Download Print this page

A.O. Smith ProMax SL Specifications page 2

Power direct-vent residential gas water heaters

Advertisement

RESIDENTIAL
POWER DIRECT-VENT
FIRST
HOUR
ENERGY GALLON
MODEL
NUMBER
RATING
FACTOR CAPACITY
GALLONS
GPD-40L
73
.59
70
.60
GPDX-50L
80
.58
105
.58
GPD-75L
130
123
.53
.58
GPDX-50L is supplied with 5' of 3" ABS vent pipe and must be used for the first 5' of the exhaust outlet vent system.
GPD-75L is supplied with 5' of 3" CPVC vent pipe and must be used for the first 5' of the exhaust outlet vent system.
Recovery capacity based on actual performance tests.
Water Connections – 3/4" Male on all models.
† Propane Gas – 40-Gallon: 36,000 BTU input, 27,360 BTU output.
50-Gallon: 60,000 BTU input, 43,800 BTU output.
75-Gallon: 65,000 BTU input, 49,400 BTU output.
IMPORTANT: VENTING AND COMBUSTION AIR REQUIREMENTS
Read and follow requirements shown in the Installation Manual for ProMax
Direct-Vent Gas water heaters dealing with type, placement and length of vent pipe
and vent termination, as well as clearances required to provide adequate
combustion and proper ventilation.
OPTIONAL CIRCULATING LOOP CONNECTION ASSEMBLIES
Sold separately. Kit Number 900152-2 includes two extended PEX lined nipples for side
port connections. Kit Number 900260-4 is same as 900152-2, plus two
di-electric unions and 2 brass isolation valves. For use with systems that have a check
valve in the air handler or recirculating lines.
IMPORTANT:
SEE INSTALLATION MANUAL FOR COMBUSTION AIR AND VENTING
SYSTEM REQUIREMENTS FOR POWER DIRECT-VENT WATER
HEATERS
OPTIONAL (DELUXE) ROUND HORIZONTAL
VENT TERMINATION KIT
Part Number 9002749
OPTIONAL (DELUXE) SQUARE HORIZONTAL
VENT TERMINATION KIT
Part Number 9003328
500 Tennessee Waltz Parkway, Ashland City, TN 37015
www.hotwater.com
Revised August 2007R
BTU
BTU
RECOVERY
INPUT
OUTPUT
90ºF RISE
PER HOUR PER HOUR GALLONS
NATURAL NATURAL PER HOUR
40
40,000 †
30,000 †
41
50
65,000 †
47,500 †
64
75
70,000 †
53,200 †
72
©2007 A. O. Smith Corporation
Gas Water Heaters
DIMENSIONS IN INCHES
R
VALUE
A
B
C
16
57
48-1/2
21
15
16
69-1/2
61
21
15
16
71-1/2 61-1/2 26-1/4 15-1/2
®
Power
11.5" MIN.
FROM TOP OF
HEATER TO
CENTER LINE
OF FLUE
1/2" GAS
CONNECTION
D
Maximum hydrostatic working pressure: 150 psi
For Technical Information and Automated Fax Service, call 800-527-1953.
A. O. Smith Corporation reserves the right to make product changes or improvements without prior notice.
D
E
F
G
H
8
42
17
42
8
54-1/2
17
54-1/2
8
54-1/2
17
54-1/2
C
E
4"
3" VENT
H
F
B A
G
Printed in U.S.A.
APPROX.
SHIPPING
WEIGHT
(LBS.)
224
232
352
ARGSS00407

Advertisement

loading

This manual is also suitable for:

Promax sl gpd-40lPromax sl gpdx-50lPromax sl gpd-75l