29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION
INSTRUCCIONES DE INSTALACIÓN PARA LA SECADORA
DRYER SAFETY ............................................... 1
INSTALLATION INSTRUCTIONS.................... 2
Tools and Parts ............................................. 2
Location Requirements ................................ 2
Electrical Requirements ................................ 3
Electrical Connection .................................... 4
Venting Requirements................................... 8
Plan Vent System .......................................... 8
Install Vent System...................................... 10
Install Leveling Legs .................................... 10
Level Dryer................................................... 10
Connect Vent............................................... 10
Reverse Door Swing.................................... 10
Complete Installation .................................. 11
We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety
messages.
This is the safety alert symbol.
This symbol alerts you to potential hazards that can kill or hurt you and others.
All safety messages will follow the safety alert symbol and either the word "DANGER" or "WARNING."
These words mean:
WARNING
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can
happen if the instructions are not followed.
8535829
INSTRUCTIONS
ELÉCTRICA DE 29 PULG. (73,7 CM)
Table of Contents / Índice

DRYER SAFETY

Your safety and the safety of others are very important.
DANGER
SEGURIDAD DE LA SECADORA ................. 12
Herramientas y piezas................................. 12
Requisitos de localización ......................... 12
Requisitos eléctricos ................................... 13
Conexión eléctrica ...................................... 15
Requisitos de ventilación ............................ 19
Nivelación de la secadora........................... 22
Conexión del ducto de escape................... 22
Complete la instalación............................... 24
You can be killed or seriously injured if you don't immediately
follow instructions.
You can be killed or seriously injured if you don't follow
instructions.

Advertisement

Table of Contents
loading

Summary of Contents for Whirlpool LER4634PT

  • Page 1: Table Of Contents

    29 IN. (73.7 CM) ELECTRIC DRYER INSTALLATION INSTRUCTIONS INSTRUCCIONES DE INSTALACIÓN PARA LA SECADORA ELÉCTRICA DE 29 PULG. (73,7 CM) Table of Contents / Índice DRYER SAFETY ..........1 SEGURIDAD DE LA SECADORA ....12 INSTALLATION INSTRUCTIONS....2 INSTRUCCIONES DE INSTALACIÓN ..12 Tools and Parts ..........
  • Page 2: Installation Instructions

    INSTALLATION INSTRUCTIONS A level floor with a maximum slope of 1 in. (2.5 cm) under entire dryer. (If slope is greater than 1 in. [2.5 cm], install Tools and Parts Extended Dryer Feet Kit, Part No. 279810.) Clothes may not tumble properly and models with automatic sensor cycles Check that you have everything necessary for correct installation.
  • Page 3: Electrical Requirements

    Companion appliance spacing should also be considered. If using a power supply cord: Use a UL approved power supply cord kit marked for use with clothes dryers. The kit should contain: " " A UL approved 30 amp power supply cord, rated 120/240 volt "...
  • Page 4: Electrical Connection

    Electrical Connection Power Supply Cord Direct Wire WARNING WARNING Fire Hazard Fire Hazard Use 10 gauge solid copper wire. Use a new UL approved 30 amp power supply cord. Use a UL approved strain relief. Use a UL approved strain relief. Disconnect power before making electrical connections.
  • Page 5 Electrical Connection Options 1. Remove center terminal block screw. 2. Remove appliance ground wire (green with yellow stripes) If your home has: And you will be Go to Section from external ground connector screw. Fasten it under center, connecting to: silver colored terminal block screw.
  • Page 6 4. Place the hooked end of the neutral wire (white or center wire) 4-wire connection: Direct Wire of power supply cable under the center screw of terminal block (hook facing right). Squeeze hooked end together. IMPORTANT: A 4-wire connection is required for mobile homes Tighten screw.
  • Page 7 1. Loosen or remove center terminal block screw. 2. Place the hooked end of the neutral wire (white or center wire) of power supply cable under the center screw of terminal 2. Connect neutral wire (white or center wire) of power supply block (hook facing right).
  • Page 8: Venting Requirements

    DURASAFE™ vent products can be purchased from your dealer 2. Elbow 6. Rigid metal or flexible metal vent or by calling Whirlpool Parts and Accessories. For more 3. Wall 7. Vent length necessary to connect elbows information, see the “Assistance or Service” section of your 4.
  • Page 9 Standard exhaust installation with rigid metal or flexible Determine Vent Length metal vent 1. Select the route that will provide the straightest and most direct path outdoors. Plan the installation to use the fewest number of elbows and turns. When using elbows or making turns, allow as much room as possible.
  • Page 10: Install Vent System

    Vent Length Chart 5. Place a carton corner post under each of the 2 dryer back corners. Stand the dryer up. Slide the dryer on the corner Number of Type of Box or Angled posts until it is close to its final location. 90º...
  • Page 11: Complete Installation

    4. Use a small, flat-blade screwdriver to carefully remove 4 hinge 8. Remove door strike (5) from cabinet. Use a small, flat-blade hole plugs (4) on left side of cabinet. Insert plugs in hinge screwdriver to carefully remove 4 hinge hole plugs (6) on left holes on right side of cabinet.
  • Page 12: Seguridad De La Secadora

    INSTRUCCIONES DE INSTALACIÓN PARA LA SECADORA ELÉCTRICA DE 29 PULG. (73,7 CM) SEGURIDAD DE LA SECADORA Su seguridad y la seguridad de los demás es muy importante. Hemos incluido muchos mensajes importantes de seguridad en este manual y en su electrodoméstico. Lea y obedezca siempre todos los mensajes de seguridad.
  • Page 13: Requisitos Eléctricos

    Un contacto con conexión a tierra ubicado a unos 2 pies Para la instalación en clóset, con una puerta, se requieren (61 cm) de cualquiera de los lados de la secadora. Vea aberturas de ventilación mínimas en la parte superior e inferior “Requisitos eléctricos”.
  • Page 14 Conexión eléctrica Si el contacto de pared luce como éste: Para instalar su secadora adecuadamente, usted debe determinar el tipo de conexión eléctrica que va a usar y seguir las instrucciones que aquí se proveen para el caso. Si los códigos locales no permiten la conexión de un conector para conexión a tierra del equipo al alambre neutro, vea “Conexión opcional de 3 hilos”.
  • Page 15: Conexión Eléctrica

    Conexión eléctrica Cable de suministro eléctrico Cable directo ADVERTENCIA ADVERTENCIA Peligro de Incendio Peligro de Incendio Utilice alambres de cobre sólido de ancho 10. Use un cable de suministro eléctrico nuevo de 30 amperes con aprobación UL. Use un protector de cables con aprobación UL. Use un protector de cables con aprobación UL.
  • Page 16 Opciones para la conexión eléctrica 1. Saque el tornillo central del bloque de terminal. 2. Saque el hilo de tierra del aparato (verde con rayas amarillas) Si su casa tiene: Y usted va a Vaya a la sección del tornillo conector de tierra externo. Fíjelo debajo del tornillo conectar con: central de color plateado del bloque de terminal.
  • Page 17 3. Conecte el hilo de tierra (verde o desnudo) del cable de Conexión de 4 hilos: Cable directo suministro eléctrico al tornillo del conector de tierra externo. Apriete el tornillo. IMPORTANTE: Se necesita una conexión de alambre de cuatro 4. Coloque el extremo del hilo neutro en forma de gancho (hilo hilos para las casas rodantes y para los casos en que los códigos blanco o central) del cable de suministro eléctrico debajo del locales no permitan el uso de conexiones de 3 hilos.
  • Page 18 Conexión de 3 hilos: Cable de suministro eléctrico Conexión de 3 hilos: Cable directo Uso cuando los códigos locales permitan la conexión del Use cuando los códigos locales permitan la conexión del conductor de tierra del gabinete al hilo neutro: conductor de tierra del gabinete al hilo neutro.
  • Page 19: Requisitos De Ventilación

    3. Coloque los extremos enganchados de los otros hilos del 6. Conecte un hilo de tierra de cobre separado desde el tornillo cable de suministro eléctrico debajo de los tornillos exteriores conector de tierra externo a tierra adecuada. del bloque de terminal (con los ganchos mirando hacia la derecha).
  • Page 20: Planificación Del Sistema De Ventilación

    Los productos de ventilación DURASAFE™ pueden comprarse en su distribuidor o llamando a Piezas y Accesorios Whirlpool. Planificación del sistema de ventilación Para obtener más información tome como referencia la sección “Ayuda o servicio técnico” de sus “Instrucciones para el usuario Instalaciones típicas de escape...
  • Page 21 NOTA: Se pueden adquirir los siguientes juegos para 2. Determine la longitud del ducto de escape. instalaciones alternas en espacios limitados. Tome como La longitud máxima del sistema de ventilación depende de: referencia la sección “Ayuda o servicio técnico” de sus El tipo de ducto de escape (metal rígido o metal flexible).
  • Page 22: Instalación Del Sistema De Ventilación

    Cuadro de la longitud del ducto de escape 2. Sujete con firmeza el cuerpo de la secadora (no la parte superior o el panel de la consola). No. de Tipo de Capotas de Capotas vueltas ducto ventilación de angulares de 90º o caja o tipo codos persianas...
  • Page 23: Cómo Invertir El Cierre De La Puerta

    Puerta super ancha de vaivén lateral de posición Cómo invertir el cierre de la puerta reversible (opcional) Si lo desea, puede cambiar la dirección del cierre de la puerta del lado derecho al lado izquierdo. Puerta grande de vaivén lateral de posición reversible 1.
  • Page 24: Complete La Instalación

    4/02 Benton Harbor, Michigan 49022 8535829 Printed in U.S.A. TM DURASAFE is a trademark of Whirlpool, U.S.A. © 2002 Whirlpool Corporation. Impreso en EE.UU. TM DURASAFE es una marca de comercio de Whirlpool, EE.UU.