Kenmore 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer Installation Instructions Manual page 6

29" (73.7cm) gas dryer
Hide thumbs Also See for 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Explosion
Hazard
Use a new CSA International
approved gas supply line.
Install a shut=off valve.
Securely tighten
all gas connections.
if connected to LP, have a qualified
person make sure
gas pressure does not exceed 13" (330 ram) water
column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and
authorized service personnel.
Failure to do so can result in death, explosion, or fire.
Gas Type
Natural Gas:
This dryer is equipped for use with Natural gas. It is design-
certified by CSA International for LP (propane or butane) gases
with appropriate
conversion.
Your dryer must have the correct burner for the type of gas
in your home. Burner information
is located on the rating
plate in the door well of your dryer. If this information
does
not agree with the type of gas available, contact your local
Sears store or Sears Service Center.
LP gas conversion:
Conversion must be made by a qualified technician.
No attempt shall be made to convert the dryer from the gas
specified on the model/serial
rating plate for use with a different
gas without consulting your gas company.
Gas supply line
Must include 1/8" NPT minimum plugged tapping accessible
for test gage connection,
immediately upstream of the gas
connection to the dryer (see illustration).
1/2" IPS or NPT pipe is recommended.
3/8" approved aluminum or copper tubing is acceptable
for lengths under 20 ft (6.1 m) if local codes and gas
supplier permit.
If you are using Natural gas, do not use copper tubing.
Lengths over 20 ft (6.1 m) should use larger tubing and
a different size adapter fitting.
If your dryer has been converted to use LP gas, 3/8" LP
compatible copper tubing can be used. If the total length
of the supply line is more than 20 ft (6.1 m), use larger pipe.
NOTE: Pipe-joint compounds
that resist the action of
LP gas must be used. Do not use TEFLON e_ttape.
Must include a shutoff valve:
An individual shutoff valve must be installed within six (6) feet
(1.8 m) of the dryer in accordance with the National Fuel Gas
Code, ANSI Z223.1. The shut off valve location should be easy
to reach for opening and closing.
E
B
A. 3/8" flexible gas connector
B. 3/8" pipe to flare adapter fitting
C. 1/8" NPT minimum plugged
tapping
D. 1/2" NPT gas supply line
E. Gas shutoff valve
Gas supply connection
requirements
Use an elbow and a 3/8" flare x 3/8" NPT adapter fitting
between the flexible gas connector and the dryer gas pipe,
as needed to avoid kinking.
Use only pipe-joint compound.
Do not use TEFLON °t tape.
This dryer must be connected to the gas supply line with a
listed flexible gas connector that complies with the standard
for connectors for gas appliances, ANSI Z21.24.
Burner input requirements
Elevations up to 10,000 ft (3,048 meters):
The design of this dryer is certified by CSA International for
use at altitudes up to 10,000 ft (3,048 m) above sea level at
the Btu rating indicated on the model/serial
number plate.
Burner input adjustments
are not required when the dryer
is operated up to this elevation.
Elevations above 10,000 ft (3,048 meters):
When installed above 10,000 ft (3,048 m) a 4% reduction of
the burner Btu rating shown on the model/serial number plate
is required for each 1,000 ft (305 m) increase in elevation.
Gas Supply Pressure Testing
The dryer must be disconnected
from the gas supply piping
system during pressure testing at pressures greater than
1/2 psi.
Dryer Gas Pipe
The gas pipe that comes out through the rear of your dryer
has a 3/8" male pipe thread.
//
A
/
_--- 9¼" ---_
(235 mm)
A. 3/8" NPT dryer pipe
11/4"
(32 rnm}
+
1-®TEFLON
is a registered
trademark
of E.I. Du Pont De Nemours and Company.
6