Kenmore 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer Installation Instructions Manual page 5

29" (73.7cm) gas dryer
Hide thumbs Also See for 7965 - 600 5.9 cu. Ft. Capacity Gas Flatback Dryer:
Table of Contents

Advertisement

Available languages

Available languages

Dryer D imensions
151/4"
i
223/4 ''
43W'/J [----
, -l(387 mr.)
,, i I E-------,-__(57--8 r.m)
/ IL JL)I
*26"_ Ik I _
-"_-d
'273/4'_t_ II_'---J
II
(66o r.m) \l_
(7o5 ram)kJ_
-'--J
(737mr")
(737ram)
A
B
223/4 ''
_/_" i l II .--------.-,% (578 r"nl
433/8 "
49mr.)
(705r"m},__\
_
(705mr")
(737r"m)
(737mr"}
C
D
A. Small opening side-swing
door
B. Large opening side-swing door
C. Wide opening side-swing
door
D. Wide opening hamper door
*Most installations require a minimum 5" (127 mm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum
spacing for recessed
area or closet
installation
The following spacing dimensions are recommended
for this
dryer. This dryer has been tested for spacing of 0" (0 mm)
clearance on the sides and rear. Recommended
spacing
should be considered for the following reasons:
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door,
and floor moldings.
Additional spacing should be considered on all sides
of the dryer to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
_
_-_in._
(310 cm)2"_
24in. _ *÷
(155 cm)2
1"_ I_ 29"-H I<- 1"÷h"*h 27'l,"Hs,!,"F-
(25ram)(737mm) (25mm) (25mm)(705mm)(140mm)
A
B
.__
3 I1.
(76 rnm)
(76mm)
A. Recessed area
B. Side view - closet or confined area
C. Closet door with vents
*Required spacing
Mobile Home - Additional
Installation
Requirements
This dryer is suitable for mobile home installations. The
installation must conform to the Manufactured
Home
Construction
and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280).
Mobile
home installations
require:
Metal exhaust system hardware, which is available for
purchase from your local Sears store or Sears Service dealer.
Mobile home Installation Kit Part Number 346764. See "Tools
and Parts" section for information
on ordering.
Special provisions must be made in mobile homes to
introduce outside air into the dryer. The opening (such as a
nearby window) should be at least twice as large as the dryer
exhaust opening.
Electrical
Shock Hazard
Plug into a grounded
3 prong outlet.
Do not remove ground
prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions
can result in death,
fire, or electrical
shock.
A 120 Volt, 60 Hz., AC only, 15- or 20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended.
It is recommended
that a separate circuit
serving only this dryer be provided.
GROUNDING
INSTRUCTIONS
[] For a grounded, cord-connected
dryer:
This dryer must be grounded. In the event of malfunction
or
breakdown,
grounding will reduce the risk of electric shock
by providing a path of least resistance for electric current.
This dryer is equipped with a cord having an equipment-
grounding conductor
and a grounding plug. The plug must
be plugged into an appropriate
outlet that is properly
installed and grounded in accordance
with all local codes
and ordinances.
WARNING:
improper connection of the equipment-
grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or service representative
or personnel if you are in doubt as to whether the dryer is
properly grounded. Do not modify the plug provided with
the dryer: if it will not fit the outlet, have a proper outlet
installed by a qualified electrician.
SAVE THESE INSTRUCTIONS