If you have questions regarding the contents of the manual, please contact our Technical Service Department at ACR Electronics, Inc., Telephone +1 (954) 981-3333 or email service@acrelectronics.com. Please be ready to provide the technician with the page number you wish to discuss.
RCL-50B, 12/24V REMOTE CONTROL SEARCHLIGHT SYSTEM SEARCHLIGHT Figure 1- Remote Control Searchlight System SECTION 1 - FOREWORD Congratulations and thank you for purchasing the ACR RCL-50B Searchlight. The combination of computer aided design, high quality raw materials, and quality-controlled manufacturing produce a superior product. The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man.
SECTION 2 - GENERAL The RCL-50B was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The RCL-50B searchlight system contains a narrow beam searchlight that produces 80,000 peak candle power by combining a 55W halogen lamp on the 12V version or a 70W halogen lamp on the 24V version with our unique optical quality parabolic reflector.
After the coax cable has been routed and the “F” connectors attached to the coax cable, simply screw the “F” connectors to the Master Controller and the Point Pad™. The cable and connectors are available either through ACR Electronics, your local Radio Shack or other sources of electronic hardware.
Page 7
Additional Point Pads™ (up to three (3) pads) may be used with one (1) Master Controller. A standard "T" connector or RG-59 television type "splitter" is used for each additional Point Pad (see Figure 2). Limit the total length of all coax cable used to 300 feet.
Page 8
Figure 3- URP-102 Point Pad™ Functions URP-102 Point Pad Functions Press the ON/OFF button to turn the lights ON or OFF. Press the SPEED button to toggle between High and Low rotation speeds. Press the Right or Left Arrows to rotate the Searchlight in that direction. Press the Up or Down Arrows to raise or lower the Searchlight-beam.
Page 9
Figure 4- URP-102 Point Pad™ Surface Mount Case Figure 5- URP-102 Point Pad™ Flush Mount Case Y1-03-0141D...
Figure 6- URP-102 Point Pad™ Surface Mount Case with gasket and Flush Mount Case with gasket SECTION 6- URC-102 Master Controller Mounting The Master Controller can be mounted in any position near the searchlight that is protected from the weather. Check in advance that the coax cable from the Point Pad™ and the wiring harness from the searchlight can be routed to this location.
Page 11
WARNING: This wire MUST be fused with a 15 amp fuse in the Master Controller's in-line fuse-holder. Wiring to Searchlight The RCL-50B searchlight is supplied with a 12-foot integral wire harness. This wire harness is cut to this length specifically to allow for a voltage drop. Shortening the harness will decrease the life of the bulbs.
Page 12
The URC-102 Master Controller has the unique XRCiZ™ feature. The XRCiZ™ feature routinely operates all moving parts in the searchlight to keep the motors and drive mechanism freely running. Once activated, and every 30 days thereafter, the XRCiZ™ feature wakes up and operates the searchlight. The searchlight will rotate 360 in both directions and the parabolic reflectors will move to the full up and down positions.
Page 13
Power Source Fuse Spotlight 12 VDC or 24 VDC Master Controller in-line 15 amp fuse Ground Blue Orange Yellow Lamp Power Green Lamp Ground Spot Up Master White Spot Down Brown Spot Left Black Spot Right 75 ohm TV Coaxial Cable “T”...
A quartz-halogen bulb is provided with your RCL-50B. If the bulb should need replacement, it can be ordered through an ACR dealer or through ACR Electronics. The part numbers are P/N 6002 for 12V units and P/N 6010 for 24V units.
Page 17
Adapter Plate, Flush mount A1-18-1871 Adapter Plate, Surface mount A1-18-1892 Instruction Sheet, Point Pad™ Y1-06-0179 Mounting Templates Y1-03-0138-1 Product No. 1929.1 - Wiring Kit RCL-50 / 100 series searchlights includes: Description Quantity ACR Part Number Connector, “F” A1-03-0220 Cable, Coaxial 15ft...
Page 18
Product No. 9282.3 – URP-102 Point Pad™ Secondary Station Installation Kit includes: Description Quantity ACR Part Number Point Pad™, URP-102 with Surface A3-06-2230 Mount case Case, Flush Mount A1-18-1875-2 Gasket, Surface Mount A1-25-0140-1 Gasket, Flush Mount A1-25-0140-2 U Clamp A1-17-1366 Nuts, Nylon-lock A1-05-0776 Washers...
1 (one) year* from date of purchase or receipt as a gift. During the warranty period ACR Electronics, Inc. will repair or, at its option, replace the unit at no cost to you for labor, materials and return transportation from ACR. For further assistance, please contact our Technical Service Department at ACR Electronics, Inc., 5757...
Page 20
EC DECLARATION OF CONFORMITY ACR Electronics, Inc. hereby declares that the following product is in conformity with Directive 2004/108/EC of the European Parliament and of the Council of 15 December 2004 on Electromagnetic Compatibility (EMC Directive). In accordance with the Directive, the product will be marked with the CE conformity marking as...