Summary of Contents for ACR Electronics RCL-100 SEARCHLIGHT
Page 1
Product Support Manual RCL-100D™ Remote Control Searchlight Master Controller Point Pad Y1-03-0138 Rev. K ACR Electronics, Inc. 5757 Ravenswood Road Fort Lauderdale, Fl 33312 Tel : +1(954) 981-3333 Fax: +1 (954) 983-5087 www.acrelectronics.com Email: Info@acrelectronics.com...
RCL-100D TABLE OF CONTENTS SECTION TITLE PAGE Forward General Searchlight Remote Control System URP-102 Point Pad™ URC-102 Master Controller RCL-100D Specifications Bulb Replacement RCL-100D Searchlight Components 10.0 Remote Control System Components FIGURES TITLE PAGE Figure 1 Remote Control Searchlight System Figure 2 Point Pad™...
RCL-100D, 12/24V REMOTE CONTROL SEARCHLIGHT SYSTEM FIGURE 1: REMOTE CONTROL SEARCHLIGHT SYSTEM FORWARD Congratulations and thank you for purchasing the ACR RCL-100D Searchlight. The combination of computer aided design, high quality raw materials, and quality-controlled manufacturing produce a superior product. The Test Facility at ACR can reproduce some of the harshest environmental conditions known to man.
GENERAL The RCL-100D was specially designed for mariners who require a high intensity remote controlled searchlight that can stand up to the tough marine environment. The RCL-100D Searchlight System contains a narrow beam searchlight that produces 200,000 peak candle power by combining two 55W halogen lamps with our unique optical quality parabolic reflectors.
“F” connectors attached to the coax cable, simply screw the “F” connectors to the Master Controller and the Point Pad™. The cable and connectors are available either through ACR Electronics, your local Radio Shack or other sources of electronic hardware.
Page 6
URC-102 URC-102 Master Master Controller Unit Controller Unit RG-59 Coaxial Cable RG-59 Coaxial Cable Fuse Fuse “T” Conn. URP-102 or Splitter Point Pad RG-59 Coaxial Cable Power Power Source Source URP-102 Point Pad RG-59 Coaxial Cable URP-102 Point Pad Single Point Pad ™ Multiple Point Pads ™...
Page 7
URP-102 Point Pad Functions • Press the ON/OFF button to turn the lights ON or OFF. • Press the SPEED button to toggle between High and Low rotation speeds. • Press the Right or Left Arrows to rotate the Searchlight in that direction. •...
Page 8
FIGURE 4: URP-102 POINT PAD™ SURFACE MOUNT CASE Y1-03-0138 Rev. J...
Page 9
FIGURE 5: URP-102 POINT PAD™ FLUSH MOUNT CASE Y1-03-0138 Rev. J...
Page 10
FIGURE 6: URP-102 POINT PAD™ Surface Mount Case with gasket and Flush Mount Case with gasket Y1-03-0138 Rev. J...
Wiring to Searchlight The RCL-100 Searchlight is supplied with a 15 foot integral wire harness. This wire harness is cut to this length specifically to allow for a voltage drop. Shortening the harness will decrease the life of the bulbs. Any extra length of wire harness should be loosely coiled in a convenient place.
Page 12
Wiring to Power Supply The power source must be a fused 12 VDC, 10-amp supply or 24 VDC, 5-amp supply. Following the wiring scheme in Table 1, use the supplied butt connectors to connect the Master Controller to the Power Source. Refer to Table 2 for proper wire size for connection of the input power lines.
Page 13
The URC-102 Master Controller provides optimum voltage to ensure the brightest Searchlight performance and long bulb life. Also to extend lamp life, the Master Controller has a timed lamp power up feature. The Searchlight lamps reach full intensity within 2 seconds. The URC-102 Master Controller has a Searchlight motor timeout feature.
RCL-100D SPECIFICATIONS (with URC-102 Controller) Specifications 12V UNIT 24V UNIT Mirror Diameter 4" x 2-3/4" Same Rated Voltage (Volt) 12 to 16 VDC 24 to 31 VDC Rated Current (A) Applicable Lamp 55W Halogen 55W Halogen Lamp x 2 Lamp x 2 (Base-G6.35) (Base-G6.35) JCD12V-55WDX...
Page 16
ACR/RCL-100D ITEM NO. DESCRIPTION PART NUMBER Front Glass HRMK 1300 Front Frame HRMK 2101 Window Weather Strip HRMK 1201 Screw M4x18 HRMK 1600 Washer M408 HRMK 9301 Gasket of front frame HRMK 2200 10 cm reflector HRMK 1301 Protection Cover HRMK 2102 O-Ring #594 HRMK 2202...
BULB REPLACEMENT Two 55W, quartz-halogen bulbs are provided with your RCL-100D. If they should need replacement, they must be ordered through ACR Electronics, by P/N A1-14-0080-1 (12V units) or A1-14-0080-2 (24V units). To replace the lamps: Disconnect unit from power source and allow bulbs to cool.
Description Quantity ACR Part Number Searchlight, RCL-100D, 24 V A3-06-1106-4 Kit, Nylon Washers (4) A3-06-1940 Connector, “F” A1-03-0220 Cable, Coaxial A2-07-0002-6 Master Controller, URC-102 A3-06-2231 Connector, "In-Line" A1-03-0222 Point Pad™, URP-102 with Surface Mount Case A3-06-2230 Case, Flush Mount A1-18-1875-2 Gasket, Surface Mount A1-25-0140-1 Gasket, Flush Mount...
Page 19
Instruction Sheet, Point Pad™ Y1-06-0179 Mounting Templates Y1-03-0138-1 PRODUCT NO. 1929.1 - Wiring Kit RCL-50 / 100 Series Searchlights Includes: Description Quantity ACR Part Number Connector, “F” A1-03-0220 Cable, Coaxial A2-07-0002-6 PRODUCT NO. 9282.3 – URP-102 Point Pad™ Secondary Station Installation Kit includes: Description Quantity ACR Part Number...
Page 20
PRODUCT NO. 9283.3 – Remote Control Installation Kit Includes: Description Quantity ACR Part Number Master Controller, URC-102 A3-06-2231 Connector, "In-Line" A1-03-0222 Point Pad™, URP-102 with Surface Mount Case A3-06-2230 Case, Flush Mount A1-18-1875-2 Gasket, Surface Mount A1-25-0140-1 Gasket, Flush Mount A1-25-0140-2 U Clamp A1-17-1366...