System Shutdown; Voltage Related System Shutdown; Temperature Related System Shutdown - IBM 6000R - Netfinity - 8682 Hardware Maintenance Manual

Hardware maintenance manual
Hide thumbs Also See for 6000R - Netfinity - 8682:
Table of Contents

Advertisement

System shutdown

Refer to the following tables when experiencing system
shutdown related to voltage or temperature problems.

Voltage related system shutdown

Message
System shutoff due to "X"
V over voltage (level-
critical; system shutoff due
to "X" supply over voltage)
System shutoff due to "X"
V under voltage (level-
critical system shutoff due
to "X" supply under voltage)

Temperature related system shutdown

Message
System shutoff due to CPU
"X" over temperature
(level-critical; CPU "X" is
over temperature)
System shutoff due to CPU
"X" under temperature
(level-critical; CPU "X" is
under temperature)
System shutoff due to
DASD temperature (sensor
X) (level-critical; DASD area
reported temperature outside
recommended operating
range)
System shutoff due to high
ambient temperature (level-
critical; high ambient
temperature)
Action
1. Check power supply
connectors
2. Replace power supply
3. Replace power
backplane
1. Check power supply
connectors
2. Replace power supply
3. Replace power
backplane
Action
1. Ensure system is
being properly
cooled, see
"Temperature
checkout" on page
27.
2. Replace CPU "X"
1. Ambient
temperature must
be within normal
operating
specifications (see
"Features and
specifications" on
page 3.
2.
1. Ensure system is
being properly
cooled, see
"Temperature
checkout" on page
27.
1. Ambient
temperature must
be within normal
operating
specifications (see
"Features and
specifications" on
page 3.
Symptom-to-FRU index
185

Advertisement

Table of Contents
loading

Table of Contents