Feed Water Valve
Cold Water Line Only
Inlet-1/2" Natural
WARNING: Do not install a pressurized storage
tank on the system's permeate line (Product
Water Tube, blue). Doing so will cause damage
to system.
6
Rev B
Drain Connection - Depending on plumbing codes, the waste water
may need to go to drain through an anti-siphon air gap. A detachable
faucet air gap is included with the system. If discharging into the utility
sink or standpipe, an air gap of greater than 1.5 inches above the flood
rim must be provided.
Do not connect the system drain line to the dishwasher drain or near
the garbage disposal. Back pressure from these units may cause the
air gap to overflow.
NOTE: All plumbing should be done in accordance with state and
local plumbing codes.
Some codes may require installation by a licensed plumber; check
with the local plumbing authority prior to installation.
In restricted under-sink areas, it may be easier to install the faucet first.
Allow adequate tubing lengths for final system placement.
Dispensing Faucet
Waste Concentrate
3/8" Black
Figure 1 Typical Under-Sink Installation
with Air Gap
Drain - 1/2" Red
Product - 3/8" Blue
Drain Coupling
Install above P trap
1/4" Blue
Carbon Postfilter
THE BASIC REVERSE OSMOSIS SYSTEM
Note: If a flush tank is not
installed the manifold
connection must remain
plugged. Removal of
plug will cause a system
leak.
Flush Tank
(optional)
RO Assembly