SABINE FBX-1020 Operating Manual

SABINE FBX-1020 Operating Manual

Feedback exterminator

Advertisement

QUICK-START OPERATION
DECLARATION OF CONFORMITY
ABOUT THE FBX-1020
F
R
REQUENCY
ESPONSE
W
'
B
F
C
ORLD
S
EST
EEDBACK
ONTROLLER
W
N
FBX?
HO
EEDS
W
FBX?
HY THE
D
H
F
!
IRECT
IT ON
EEDBACK
A
/B
S
CTIVE
YPASS
WITCH
S
L
IGNAL
EVEL
R
ESET
S
T
N
F
ET
OTAL
UMBER OF
ILTERS
S
F
ET
IXED
A/C P
I
OWER
NPUT
A
I
& O
UDIO
NPUTS
UTPUTS
FBX-1020 CONTROLS
L
F
F
OCK
IXED
ILTERS
F
O
IFTH
CTAVE
F
S
A
ILTER
TAGE
CTIVITY
P
S
OWER
WITCH
F
USE
APPLICATION DIAGRAMS
FBX S
M
ETUP FOR
ONITORS
FBX S
E
M
ETUP FOR
NTIRE
IX
QUICK-START OPERATION
For best results, read all operating instructions before using the FBX-1020. If you're already familiar with the FBX or just
want a basic overview of FBX operation, this simple quick-start procedure is for you. More detailed instructions are on
page 7 inside this operating guide.
1. Place the FBX between the output of your mixer and the input of your power amp.
2. With the master volume down, put the FBX-1020 in active mode (red BYPASS LED off), then slowly raise the mixer master
volume to the point of feedback.
3. Keep raising the master volume until all of your fixed filters and one dynamic filter are set, then lower the volume slightly.
(Factory default is nine fixed and three dynamic filters.) The rest of the filters continually catch and update new feedback
frequencies throughout the program. You're ready to go.
CONGRATULATIONS! You now have the state-of-the-art in feedback control. Your Sabine FBX-1020 Feedback Exterminator
20-bit digital filtering device — gives you automatic real-time feedback control and increases the clarity and volume of your system.
The FBX-1020 incorporates the latest in digital signal processing technology. It automatically senses feedback in a sound system and determines
its pitch. It then places one of 10 Constant Q micro-filters on the resonating frequency and eliminates the feedback in typically less than one second.
Special features of the FBX-1020:
An improved algorithm that allows the FBX-1020 to better distinguish the difference between feedback and music
Improved 20-bit digital resolution, providing superior dynamic range and signal-to-noise ratio
10 feedback filters, giving the unit more feedback elimination power for the toughest venues.
ClipGuard™ adaptive clip level control, with TURBO setup mode, increases the effective dynamic range by more than 10dB
and makes setup faster and easier.
Standard FBX features such as lockable fixed filters and switchable 1/10- and 1/5-octave Constant Q filters are also included
and now have convenient front panel switches.
OPERATING GUIDE
1
2
3
3
3
3
3
3
4
4
4
4
4
4
4
4
4
4
4
4
4
5
5
5
READ THE ENTIRE OPERATING GUIDE FOR COMPLETE INSTRUCTIONS.
V2
FBX-1020 OPERATING INSTRUCTIONS
W
FBX
HERE THE
FITS IN YOUR SOUND SYSTEM
A
NOTE ABOUT GRAPHIC EQUALIZERS
U
FIXED & DYNAMIC
NDERSTANDING
C
G
™ A
C
L
LIP
UARD
DAPTIVE
LIP
C
G
TM TURBO M
LIP
UARD
ODE
FBX S
S
I
ETUP FOR
INGLE
NSERT
FBX S
I
S
ETUP FOR
NSERT
END
H
T
O
T
FBX-1020
OW
O
PERATE
HE
H
T
U
T
FBX-1020 F
OW
O
SE
HE
U
LOCK FIXED
SING THE
FEATURE
S
ELECTING FILTER WIDTH
I
O
C
MPORTANT
PERATING
ONSIDERATIONS
M
EMORY
B
M
YPASS
ODE
R
ESETTING THE FILTERS
TURBO M
S
ODE
ETUP
D
T
M
EFEATING
URBO
ODE
M
. S
M
OBILE VS
TATIONARY
ICROPHONES
FREQUENTLY ASKED QUESTIONS
INDEX
FBX-1020 ENGINEERING SPECIFICATIONS
CAUTIONS & WARNINGS
LIMITED WARRANTY
6
6
6
6
FILTERS
C
6
EVEL
ONTROL
G
6
UIDE
P
7
OINT
& R
7
ETURN
7
8
EATURES
8
8
8
8
8
8
8
8
8
9
9
10
11
12
®
— a single channel,

Advertisement

Table of Contents
loading

Summary of Contents for SABINE FBX-1020

  • Page 1 1. Place the FBX between the output of your mixer and the input of your power amp. 2. With the master volume down, put the FBX-1020 in active mode (red BYPASS LED off), then slowly raise the mixer master volume to the point of feedback.
  • Page 2: Declaration Of Conformity

    Serial No.: Year of Manufacture: 1997 and on I, the undersigned, herby declare that the equipment specified above conforms to the above Directive and Standard. Place: Alachua, Florida, USA Signature: Date: October 4, 2000 Full Name: Doran Oster, Sabine President...
  • Page 3: About The Fbx-1020

    Over the years, engineers stopped using 12-band EQs in favor of the narrower-filter 31-band EQ for controlling feedback. The FBX represents the next step. An EQ would need more than 10,000 sliders to be equivalent to your FBX. With the FBX-1020, your monitors will finally sound loud enough, everyone in the audience will understand each word, and the mains will sound natural and transparent.
  • Page 4: A Ctive /B Ypass S Witch

    FBX-1020 Back Panel A/C Power Input Fuse The FBX-1020 is factory configured to operate at either 115 VAC This equipment is fitted with an IEC power inlet incorporating or 230 VAC. Using the wrong input voltage may cause perma- a built-in fuse holder. To change the fuse in this socket: nent damage to the unit and will void the warranty.
  • Page 5: Application Diagrams

    APPLICATION DIAGRAMS FBX Setup for Monitors FBX Out FBX IN Amp In Monitor OUT Amplifier FBX Setup for Entire Mix FBX OUT Amp IN Amplifier FBX IN All other Signal Processing Equipment Main OUT...
  • Page 6: W Here The Fbx Fits In Your Sound System

    If you use an equalizer, place the FBX after the EQ in the signal path. during setup. The FBX-1020 is set in TURBO mode at the Use the EQ’s controls to shape the tonal response of the sound factory and automatically engages every time you system, but DO NOT NOTCH FOR FEEDBACK.
  • Page 7 TURBO setup corresponding to the desired number of fixed filters lights, mode. Otherwise, the FBX-1020 will clip and may set FBX press the SET FIXED button. You've successfully set the filters improperly. (Clip level is set to the lowest level so number of fixed filters.
  • Page 8: Important Operating Considerations

    Mobile vs. Stationary Microphones Bypass Mode One significant advantage offered by the Sabine family of FBX The FBX has a true power-off bypass. The signal is unaffected feedback eliminator products is their ability to adapt to chang- in BYPASS MODE even if the unit is turned off.
  • Page 9: Frequently Asked Questions

    CLIP LED flashes when no other signal level LEDs are disconnected from the back of the unit. on, the FBX-1020 is still in TURBO mode. TURBO mode turns off automatically after the first dynamic filter is set, or Q. Can I mix balanced and unbalanced inputs and outputs? you can turn it off manually by pressing the LOCK FIXED Yes.
  • Page 10: Fbx-1020 Engineering Specifications

    FBX-1020 ENGINEERING SPECIFICATIONS THD: <0.02% @ 23 dBV sine wave at 1 KHz FILTERS 10 independent digital notch filters, controlled automatically from 40 Dynamic Range: >110 dB with ClipGuard™ automatic clip level Hz to 20 KHz. control active Filter width: user-controllable, either 1/10 or 1/5 oct., Constant Q POWER INPUT Factory configured to either 115 VAC or 230 VAC.
  • Page 11: Cautions And Warnings

    CAUTIONS & WARNINGS Warning! Warning! This equipment must be earthed. Caution! Risk of electric shock. Do not open. Caution! Shock hazard. Do not remove covers. No user serviceable parts The unit is designed to operate from standard AC power. Please be inside.
  • Page 12: Limited Warranty

    NOTE: Keep the PROOF OF PURCHASE. In the event warranty service is required during the SABINE, INC. warranty period, you will need this document. There will be no identification card issued by Sabine, Inc. 13301 HIGHWAY 441 IMPORTANCE OF WARRANTY REGISTRATION CARDS AND NOTIFICATION OF CHANGES...

Table of Contents