Juniper STRM 2008.2 - RELEASE NOTES Release Note page 9

Advertisement

Not all trusted certificates have an Intermediate key. Verisign certificates are one
example that uses an Intermediate key. The overall impact of this problem
depends on your particular deployment. The upgrade may fail because the
configuration file is missing a line that provides the directory path to your custom
certificate key on the server.
Workaround: Follow these steps to update the configuration file and restart
services:
Open the configuration file on the machine that uses the custom SSL key (normally
Step 1
the Web Server console.
Add the directory path to your custom SSL key.
Step 1
Restart the hostcontext service using the following command:
Step 2
service hostcontext restart
Infranet Controller Device Appears as Enterasys Device
An auto-discovered Infranet Controller (IC) device may appear incorrectly as an
Enterasys device.
Workaround: Add the Infranet Controller device manually.
Infranet Controller Device Appears as Secure Access Device
An auto-discovered Infranet Controller (IC) device may appear incorrectly as a
Secure Access (SA) device.
Workaround: Add the Infranet Controller device manually.
Exporting Information Using CSV/XML Export may be Blocked Using Internet
Explorer 7
If you wish to download information (such as events, assets, or flows), using the
STRM Export function, you can select the Notify When Done option that enables
the browser to notify you when the download is complete. However, if you are
using Internet Explorer 7, a warning appears requiring you to select an option
menu to download the file. When you select the option menu, the browser
refreshes to the STRM Dashboard and the exported file is not downloaded.
Workaround: In Internet Explorer 7, change the Security Settings > Downloads >
Automatic Prompting for file downloads option to Enable.
Continuous Use of STRM Over Extended Period of Time May Cause Interface
Failure
If you continue to use a session of the STRM interface for an extended period of
time, a failure may occur in your browser requiring you to restart your system. This
failure is a result of a memory loss due to a limitation in the web browser
architecture.
Workaround: Restart your browser if your browser performance degrades.
Known Issues and Limitations