Download Print this page

Troubleshooting Hints; Repair And Replacement Parts - Field Controls 46285300 Manual

24 vac system control kit

Advertisement

PRESSURE SWITCH FOR WATER HEATER
1. Follow water heater manufacturer's instructions to light pilot. Turn the gas control valve to the ON position. Then
adjust the thermostat to call for heat, which will energize the venter motor. (May see a 1 to 8 sec. delay of venter
motor)
2. Turn gas control valve to the PILOT position, which will start a 1 to 3 min. post purge of the venter motor.
3. Repeat Step 1 and 2 to ensure proper operation.
SPILLAGE SWITCHES
1. Allow the water heater to heat up to operating temperature, then disconnect the power to the gas pressure switch.
2. Adjust the thermostat to call for heat with the venter inoperative. Allow approximately 2 minutes of flue gas spillage for
the spillage switches to sense the spillage and disrupt the thermocouple circuit, halting the gas flow to the pilot and
burner.
3. Wait 2 to 3 minutes. Reset the spillage switches and light the pilot, then perform a second safety spillage test (Steps 1
and 2).
CAUTION: If for any reason the system has shut down during operation, the cause of the system failure should be
investigated and corrected before resetting the safety switch and restarting the system.
TROUBLE SHOOTING HINTS
1. Venter does not activate when thermostat calls for heat.
a. Check wiring.
b. Check gas pressure switch for continuity across terminals when gas valve is pressurized.
c. Check gas pressure.
2. Flue gas odor:
a. Check system draft.
b. Check for negative pressure in building.
3. Pilot will not stay lit on water heater:
a. Solder all spillage switch wire terminal connections.
b. Check reset buttons on spillage switches.

REPAIR AND REPLACEMENT PARTS

TCA-2 Left Handed Thermocouple Adaptor
MODEL
Gas Pressure Switch
GSK-3 Spillage Switch
Post Purge Timer
Pressure Switch
TCA-1 Thermocouple Adaptor
PART NUMBER
46284200
46086400
46282800
46083000
46082700
46429900
Page 7

Advertisement

loading

This manual is also suitable for:

Ck-91fCk-91fg