Installation Instructions; Remove Mounting Plate; Rotate Air Deflector - Whirlpool GH5184XPB Installation Instructions Manual

Installation instructions
Table of Contents

Advertisement

Remove Mounting Plate

NOTE: To avoid possible damage to the work surface, cover the
work surface.
1. Remove any remaining contents from the microwave oven
cavity.
2. Remove the mounting plate and set aside.
A
A. Mounting plate
B. Back of microwave oven
3. Tape the microwave oven door closed so that door does not
swing open while the microwave oven is being handled.
NOTE: To avoid damage to the microwave oven, do not grip or
use the door or door handle while the microwave oven is being
handled.
4

INSTALLATION INSTRUCTIONS

B

Rotate Air Deflector

The microwave oven is set for recirculation installation. For wall or
roof venting, changes must be made to the venting system.
NOTE: Skip this section if you are using recirculation installation.
Keep the damper assembly in case the venting method is
changed, or the microwave oven is reinstalled in another location
where wall or roof venting may be used.
Wall Venting Installation Only
1. Remove screws attaching damper plate to top of microwave
oven exterior, then slide damper plate away from retaining
tabs.
A
A. Retaining tabs
B. Damper plate
2. Keep damper plate and screws together and set aside.
3. Slide air deflector out of microwave oven.
A
A. Air deflector
4. Rotate air deflector front to back so that deflector feet face the
front of the microwave oven, and then slide air deflector into
the back of the microwave oven as shown, making sure its
exhaust port (open end) aligns with the microwave oven
exhaust port.
C
A. Microwave oven exhaust port
B. Deflector feet
C. Air deflector exhaust port (open end)
B
A
B

Hide quick links:

Advertisement

Table of Contents
loading