Install the power cord.
The rear access cover must be removed. To remove, loosen
center screw (one screw) and remove access cover. The
terminal block will then be accessible (See Fig. 30).
Range Connection
Opening
Size Chart
Supply Cord Kit ampere rating information.
See serial plate on range
for kilowatt
rating
data.
See Serial Plate on Range for
KW Rating
120/240 Volts 120/208 Volts
Cord Kit
Ampere
Rating
8.8-16.5 KW
7.9-12.5 KW
40/50 Amp
16.6-22.5
KW
12.6-18.5
KW
50 Amp
Fig.
29
Diameter
(inches) of Range
connection
Opening
Permanent
Cord Kit
Wiring
1-3/8 in.
1-1/8 in.
1-3/8
in.
1-3/8 in.
/
Remove
Access
Cover to install
Power Cord.
Replace after
installation.
Fig. 30
Rear
of Range
1-1/8" Dia.
Knockout
(See Chart)
Mounting
Plate
\
7/8" Dia.
Hole
(See Chart)
Wiring
instructions
(4-wire connection
- See fig. 33)
Before wiring the range review the suggested power
source location drawing in Fig. 2. If connecting to a 4-Wire
electrical system (new branch-circuit
or mobile home
requires 4-Wire connection):
Power cord
instructions
1.
Followthemanufacturer'sinstallationinstructions
supplied with the strain relief and install (Also see
Figs. 29, 30, 31 & 32).
2.
Insert the end connectors for Line 1, Line 2 and Neutral
and tighten securely to the terminal block.
IMPORTANT
NOTE: DO NOT LOOSEN the factory
installed nut connections which secure the range
wiring to the terminal block. Electrical failure or loss of
electrical connection
may occur if these 3 nuts are
loosened or removed.
3.
You must disconnect
the ground strap.
Remove
the factory installed ground screw & plate to release
the copper ground strap from the frame of the
appliance. Cut and discard the copper ground strap &
plate. KEEP the ground screw.
4.
Connect the ground wire (Green) lead with the eyelet to
the frame of the appliance with the ground screw using
the same hole in the frame where the ground screw
was originally installed (See Fig. 33).
5.
Make sure all screws are tightened securely and
replace the rear access cover (See Fig. 30).
Power
Cord Strain
Relief Bushing
Separate
Power Cord
Strain Relief Bushing
before installation
1-3/8"
Hole
(See Chart)
Fig. 31
Pocket
for Cable
Mounting Plate