Fig. 25 - Kenmore 4812 - Elite 27 in. Double Wall Oven Installation Instructions Manual

Freestanding dual fuel

Advertisement

Anti=tip
bracket
installation
instructions
FASTEN BRACKET
(WALL
OR FLOOR
MOUNTING)
=-_1
1_1=-1=1/4 '' Max.
Leveling
Leg --
i_
t
J
_F
Wall M°unt
--
Wall Plate
Floor
Mount
L-Anti=Tip
Bracket
Fig. 24
FASTEN
BRACKET (FLOOR MOUNTING ONLY)
Leveling Leg --
-4
_-- More
Than
1 =1/4"
i
Fig. 25
Fig. 26
Fig. 27
Electrical
requirements
3 & 4 - Wire electrical
wall Receptacle
types and
recommended
mounting
orientation
on wall
Required
for new and
remodeled
installations
4 Wire Wall
Receptacle
(14150R)
Allowed
for
exisiting
installations
3 Wire Wall
Receptacle
(10=50R)
Fig. 28
Electrical
connection
requirements
This appliance must be properly installed and grounded by
a qualified technician in accordance with the National Electrical
CodeANSVNFPA No. 70-- latest edition -- and local electrical
code requ irement s.
This appliance may be connected
by means of permanent
"Hard Wiring" or "Power Supply Cord Kit."
When hard wiring,
do not leave excess wire in range
compartment. Excess wire in the range compartment may not
allow the access cover to be replaced properly, and could
create a potential electrical hazard ifwires become pinched.
Connect only as instructed under "WIRING INSTRUCTIONS"
in Step Bofthe Installation Steps. When using flexibleconduit
or range cable use flex connector or range cable strain relief
(See Fig. 32 on page 7).
NOTE: Only usecopper wire in connection toterminal block.
Models Requiring
Power Supply Cord Kit
RISK OF FIRE OR ELECTRICAL SHOCK MAY OCCUR IF AN
INCORRECT
SIZE RANGE CORD KIT IS USED, THE
INSTALLATION INSTRUCTIONS ARE NOT FOLLOWED OR
STRAIN RELIEF BRACKET IS DISCARDED.
This appliance
may be connected
by means of a power
supply cord. Only a power supply cord kit rated at 125/250
volts minimum, and marked for use with ranges shall be
used. See chart (Fig. 29) for cord kit ampere rating information.
Cord must haveeither four (4) or three (3) conductors (See Fig.
28). Terminals on end of wires must be either closed loop or
open-end spade lugs with upturned ends. Cord must have
strain relief clamp. See Step B in Installation Steps for 4 or
3 - Wire connections.