Download Print this page

Kurzweil K2500 - PERFORMANCE GUIDE REV F PART NUMBER 910252 CHAP 6 Manual page 6

Control sources

Advertisement

Control Sources
MIDI Control Source List
66
67
68
69
70—74
75
76—79
80—83
84—90
91
92—95
96
97
123
6-6
MIDI 66 (SostPD)
MIDI controller 66 is defined as Sostenuto Switch. The control assignment param-
eter FootSw2 is set by default to MIDI controller 66, so a switch pedal on your MIDI
controller which sends MIDI 66 will send sostenuto messages to the K2500 by de-
fault. The K2500 will always respond to sostenuto messages.
MIDI 67 (SoftPd)
This is the standard MIDI controller number for Soft Pedal. The K2500 will always
respond to Soft pedal messages.
MIDI 68
MIDI 69 (FrezPd)
The K2500 will always respond to this message. It causes all notes to be frozen at
their current amplitude levels while the function is on.
MIDI 70—74
MIDI 75 (LegatoSw)
The K2500 always responds to this message. When a MIDI controller 75 message
with a value above 64 is received, the K2500 will force polyphonic programs to be
monophonic.
MIDI 76—79
MIDI 80—83 (Ctl E—H)
MIDI 84—90
MIDI 91 (FXDep)
The MIDI specification defines this controller as External Effects Depth. If the FX
Mode parameter is set to Master, and the FX Channel parameter is set to a specific
MIDI channel, the K2500 will respond to this message when it is received on the
FX channel. It responds by adjusting the Wet/Dry mix of the current preset effect.
MIDI 92—95
MIDI 96 (DataInc)
This is defined as Data Increment. It's intended to be assigned to a switch control.
When the control is on (value 127), the currently selected parameter's value will be
increased by one increment. This could be assigned to FootSw2, for example, to
scroll through the program list while in Program mode.
MIDI 97 (DataDec)
This is defined as Data Decrement. It's intended to be assigned to a switch control.
When the control is on (value 127), the currently selected parameter's value will be
decreased by one increment.
MIDI 123 (Panic)
The K2500 always responds to this message by sending an All Notes Off and All
Controllers Off message on all 16 MIDI channels.